Change history for item: Gas BIASI RINNOVA COND M160.3035SM 30.7 kW double-circuit

  1. Donny Darko 07 July 2023 17:58:36
    1. Create: Description #3371588
      Value: Type of heating boiler: gas, max. heating power: 30.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3371589
      Value: Gas, condensing
    3. Create: Burner #3371590
      Value: Gas
    4. Create: Number of circuits #3371591
      Value: Double-circuit
    5. Create: Thermal power #3371592
      Value: 7.20 - 30.70 kW
    6. Create: The combustion chamber #3371593
      Value: Closed
    7. Create: Efficiency #3371594
      Value: 102.2 %
    8. Create: Control #3371595
      Value: Electronic
    9. Create: Installation #3371596
      Value: Wall-mounted
    10. Create: Mains voltage #3371597
      Value: Single-phase
    11. Create: Peculiarities #3371598
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3371599
      Value: 7 l
    13. Create: Equipment #3371600
      Value: Display
    14. Create: Fuel #3371601
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3371602
      Value: 3.69 cu. m/hour
    16. Create: LPG consumption #3371603
      Value: 2.76 kg/hour
    17. Create: Nominal pressure of natural gas #3371604
      Value: 17 - 25 mbar
    18. Create: Permissible LPG pressure #3371605
      Value: 45 mbar
    19. Create: Heat carrier temperature #3371606
      Value: 25 - 85 °С
    20. Create: Temperature in the DHW circuit #3371607
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3371608
      Value: 14.3 l/min
    22. Create: Hot water capacity at t 30°C #3371609
      Value: 11.9 l/min
    23. Create: Hot water capacity at t 35°C #3371610
      Value: 10.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3371611
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3371612
      Value: 3 bar
    26. Create: Gas connection #3371613
      Value: 3/4"
    27. Create: Heating circuit connection #3371614
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3371615
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3371616
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3371617
      Value: Yes
    31. Create: Dimensions WxHxD #3371618
      Value: 400x700x290mm
    32. Create: Weight #3371619
      Value: 38 kg
    33. Create: Image #6315730
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id724379067714943048/orig
    34. Create: Preview image #6315731
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id724379067714943048/orig
  2. Donny Darko 30 April 2023 08:15:05
    Name: Gas BIASI RINNOVA COND M160.3035SM 30.7 kW double-circuit; Catalog: Heating boilers