Change history for item: Gas BIASI RINNOVA COND M160.2025SM 20.7 kW double-circuit

  1. Donny Darko 07 July 2023 17:58:32
    1. Create: Description #3371556
      Value: Type of heating boiler: gas, max. heating power: 20.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3371557
      Value: Gas, condensing
    3. Create: Burner #3371558
      Value: Gas
    4. Create: Number of circuits #3371559
      Value: Double-circuit
    5. Create: Thermal power #3371560
      Value: 5.70 - 20.70 kW
    6. Create: The combustion chamber #3371561
      Value: Closed
    7. Create: Efficiency #3371562
      Value: 102.9 %
    8. Create: Control #3371563
      Value: Electronic
    9. Create: Installation #3371564
      Value: Wall-mounted
    10. Create: Mains voltage #3371565
      Value: Single-phase
    11. Create: Peculiarities #3371566
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3371567
      Value: 7 l
    13. Create: Equipment #3371568
      Value: Display
    14. Create: Fuel #3371569
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3371570
      Value: 2.12 cu. m/hour
    16. Create: LPG consumption #3371571
      Value: 1.58 kg/h
    17. Create: Nominal pressure of natural gas #3371572
      Value: 17 - 25 mbar
    18. Create: Permissible LPG pressure #3371573
      Value: 45 mbar
    19. Create: Heat carrier temperature #3371574
      Value: 25 - 85 °С
    20. Create: Temperature in the DHW circuit #3371575
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3371576
      Value: 14.3 l/min
    22. Create: Hot water capacity at t 30°C #3371577
      Value: 11.9 l/min
    23. Create: Hot water capacity at t 35°C #3371578
      Value: 10.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3371579
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3371580
      Value: 3 bar
    26. Create: Gas connection #3371581
      Value: 3/4"
    27. Create: Heating circuit connection #3371582
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3371583
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3371584
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3371585
      Value: Yes
    31. Create: Dimensions WxHxD #3371586
      Value: 400x700x290mm
    32. Create: Weight #3371587
      Value: 35 kg
    33. Create: Image #6315728
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id724379067714943048/orig
    34. Create: Preview image #6315729
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id724379067714943048/orig
  2. Donny Darko 30 April 2023 08:15:05
    Name: Gas BIASI RINNOVA COND M160.2025SM 20.7 kW double-circuit; Catalog: Heating boilers