      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3371497
      Value: Gas, convection
    3. Create: Burner #3371498
      Value: Gas
    4. Create: Number of circuits #3371499
      Value: Double-circuit
    5. Create: Thermal power #3371500
      Value: 9.30 - 24 kW
    6. Create: Thermal load #3371501
      Value: 11 - 26.60 kW
    7. Create: The combustion chamber #3371502
      Value: Open
    8. Create: Efficiency #3371503
      Value: 90.2 %
    9. Create: Control #3371504
      Value: Electronic
    10. Create: Installation #3371505
      Value: Wall-mounted
    11. Create: Mains voltage #3371506
      Value: Single-phase
    12. Create: Peculiarities #3371507
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3371508
      Value: 6 l
    14. Create: Fuel #3371509
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3371510
      Value: 2.82 cu. m/hour
    16. Create: LPG consumption #3371511
      Value: 2.09 kg/h
    17. Create: Nominal pressure of natural gas #3371512
      Value: 17 - 25 mbar
    18. Create: Permissible LPG pressure #3371513
      Value: 45 mbar
    19. Create: Heat carrier temperature #3371514
      Value: 38 - 80 °С
    20. Create: Temperature in the DHW circuit #3371515
      Value: 35 - 55 °С
    21. Create: Hot water capacity at t 25°C #3371516
      Value: 16 l/min
    22. Create: Hot water capacity at t 35°C #3371517
      Value: 9.7 l/min
    23. Create: Max. water pressure in the DHW circuit #3371518
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3371519
      Value: 3 bar
    25. Create: Gas connection #3371520
      Value: 3/4"
    26. Create: Heating circuit connection #3371521
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3371522
      Value: 1/2"
    28. Create: Chimney diameter #3371523
      Value: 130 mm
    29. Create: Dimensions WxHxD #3371524
      Value: 400x703x325 mm
    30. Create: Weight #3371525
      Value: 34 kg
    31. Create: Image #6315722
      URL: https://avatars.mds.yandex.net/get-mpic/4785755/img_id2874765087785241444.jpeg/orig
    32. Create: Image #6315723
      URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id6399565052818574648/orig
    33. Create: Preview image #6315724
      URL: https://avatars.mds.yandex.net/get-mpic/4785755/img_id2874765087785241444.jpeg/orig
  2. Donny Darko 30 April 2023 08:15:04
    Name: Gas BIASI PARVA NOVA М90.24А 24 kW double-circuit; Catalog: Heating boilers