Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 17:58:15
Create:
Description #3371465
Value: Type of heating boiler: gas, max. heating power: 31.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3371466
Value: Gas, convection
Create:
Burner #3371467
Value: Gas
Create:
Number of circuits #3371468
Value: Double-circuit
Create:
Thermal power #3371469
Value: 12.70 - 31.70 kW
Create:
Thermal load #3371470
Value: 15.50 - 34.80 kW
Create:
The combustion chamber #3371471
Value: Closed
Create:
Efficiency #3371472
Value: 91.1 %
Create:
Control #3371473
Value: Electronic
Create:
Installation #3371474
Value: Wall-mounted
Create:
Mains voltage #3371475
Value: Single-phase
Create:
Peculiarities #3371476
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3371477
Value: 6 l
Create:
Fuel #3371478
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3371479
Value: 2.82 cu. m/hour
Create:
LPG consumption #3371480
Value: 2.09 kg/h
Create:
Nominal pressure of natural gas #3371481
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3371482
Value: 45 mbar
Create:
Heat carrier temperature #3371483
Value: 38 - 80 °С
Create:
Temperature in the DHW circuit #3371484
Value: 35 - 55 °С
Create:
Hot water capacity at t 25°C #3371485
Value: 18.2 l/min
Create:
Hot water capacity at t 35°C #3371486
Value: 13 l/min
Create:
Max. water pressure in the DHW circuit #3371487
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3371488
Value: 3 bar
Create:
Gas connection #3371489
Value: 3/4"
Create:
Heating circuit connection #3371490
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3371491
Value: 1/2"
Create:
Coaxial chimney diameter #3371492
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3371493
Value: Yes
Create:
Dimensions WxHxD #3371494
Value: 400x703x325 mm
Create:
Weight #3371495
Value: 39 kg
Create:
Image #6315719
URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id9075476674897819375.jpeg/orig
Create:
Image #6315720
URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id6399565052818574648/orig
Create:
Preview image #6315721
URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id9075476674897819375.jpeg/orig
Donny Darko 30 April 2023 08:15:04
Name: Gas BIASI PARVA NOVA M90.32S 31.7 kW double-circuit; Catalog: Heating boilers