Change history for item: Gas BIASI RINNOVA M290.28BM/M

  1. Donny Darko 07 July 2023 17:56:14
    1. Create: Description #3370828
      Value: Type of heating boiler: gas, max. heating power: 27.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3370829
      Value: Gas, convection
    3. Create: Burner #3370830
      Value: Gas
    4. Create: Number of circuits #3370831
      Value: Double-circuit
    5. Create: Thermal power #3370832
      Value: 11.30 - 27.60 kW
    6. Create: Thermal load #3370833
      Value: 13 - 30.60 kW
    7. Create: The combustion chamber #3370834
      Value: Open
    8. Create: Efficiency #3370835
      Value: 90 %
    9. Create: Control #3370836
      Value: Electronic
    10. Create: Installation #3370837
      Value: Wall-mounted
    11. Create: Secondary heat exchanger material #3370838
      Value: Steel
    12. Create: Mains voltage #3370839
      Value: Single-phase
    13. Create: Peculiarities #3370840
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, external control connector, thermometer, water filter
    14. Create: Expansion tank volume #3370841
      Value: 7 l
    15. Create: Equipment #3370842
      Value: Display
    16. Create: Fuel #3370843
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3370844
      Value: 3.24 cu. m/hour
    18. Create: LPG consumption #3370845
      Value: 2.41 kg/h
    19. Create: Nominal pressure of natural gas #3370846
      Value: 17 - 25 mbar
    20. Create: Permissible LPG pressure #3370847
      Value: 45 mbar
    21. Create: Heat carrier temperature #3370848
      Value: 38 - 85 °С
    22. Create: Temperature in the DHW circuit #3370849
      Value: 35 - 60 °С
    23. Create: Hot water capacity at t 25°C #3370850
      Value: 18.1 l/min
    24. Create: Hot water capacity at t 30°C #3370851
      Value: 14.8 l/min
    25. Create: Max. water pressure in the DHW circuit #3370852
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3370853
      Value: 3 bar
    27. Create: Gas connection #3370854
      Value: 3/4"
    28. Create: Dimensions WxHxD #3370855
      Value: 400x703x325 mm
    29. Create: Weight #3370856
      Value: 28.7 kg
    30. Create: Image #6315665
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id8391773932893728880.jpeg/orig
    31. Create: Preview image #6315666
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id8391773932893728880.jpeg/orig
  2. Donny Darko 30 April 2023 08:14:55
    Name: Gas BIASI RINNOVA M290.28BM/M; Catalog: Heating boilers