Change history for item: Gas BIASI RINNOVA M290.32CM/M

  1. Donny Darko 07 July 2023 17:56:05
    1. Create: Description #3370768
      Value: Type of heating boiler: gas, max. heating power: 30.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3370769
      Value: Gas, convection
    3. Create: Burner #3370770
      Value: Gas
    4. Create: Number of circuits #3370771
      Value: Double-circuit
    5. Create: Thermal power #3370772
      Value: 18 - 30.60 kW
    6. Create: Thermal load #3370773
      Value: 20 - 33.90 kW
    7. Create: The combustion chamber #3370774
      Value: Closed
    8. Create: Efficiency #3370775
      Value: 93.1 %
    9. Create: Control #3370776
      Value: Electronic
    10. Create: Installation #3370777
      Value: Wall-mounted
    11. Create: Secondary heat exchanger material #3370778
      Value: Steel
    12. Create: Mains voltage #3370779
      Value: Single-phase
    13. Create: Peculiarities #3370780
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, external control connector, thermometer, water filter
    14. Create: Expansion tank volume #3370781
      Value: 7 l
    15. Create: Equipment #3370782
      Value: Display
    16. Create: Fuel #3370783
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3370784
      Value: 3.59 cu. m/hour
    18. Create: LPG consumption #3370785
      Value: 2.67 kg/h
    19. Create: Nominal pressure of natural gas #3370786
      Value: 17 - 25 mbar
    20. Create: Permissible LPG pressure #3370787
      Value: 45 mbar
    21. Create: Heat carrier temperature #3370788
      Value: 38 - 85 °С
    22. Create: Temperature in the DHW circuit #3370789
      Value: 35 - 60 °С
    23. Create: Hot water capacity at t 25°C #3370790
      Value: 20 l/min
    24. Create: Hot water capacity at t 30°C #3370791
      Value: 16.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3370792
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3370793
      Value: 3 bar
    27. Create: Gas connection #3370794
      Value: 3/4"
    28. Create: Coaxial chimney diameter #3370795
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3370796
      Value: Yes
    30. Create: Dimensions WxHxD #3370797
      Value: 400x703x325 mm
    31. Create: Weight #3370798
      Value: 34.5 kg
    32. Create: Image #6315661
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id4870396372558463101.jpeg/orig
    33. Create: Preview image #6315662
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id4870396372558463101.jpeg/orig
  2. Donny Darko 30 April 2023 08:14:55
    Name: Gas BIASI RINNOVA M290.32CM/M; Catalog: Heating boilers