Change history for item: Gas BIASI RINNOVA M290.24CM/M

  1. Donny Darko 07 July 2023 17:55:56
    1. Create: Description #3370704
      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3370705
      Value: Gas, convection
    3. Create: Burner #3370706
      Value: Gas
    4. Create: Number of circuits #3370707
      Value: Double-circuit
    5. Create: Thermal power #3370708
      Value: 12.90 - 23.70 kW
    6. Create: Thermal load #3370709
      Value: 14.50 - 25.50 kW
    7. Create: The combustion chamber #3370710
      Value: Closed
    8. Create: Efficiency #3370711
      Value: 92.8 %
    9. Create: Control #3370712
      Value: Electronic
    10. Create: Installation #3370713
      Value: Wall-mounted
    11. Create: Secondary heat exchanger material #3370714
      Value: Steel
    12. Create: Mains voltage #3370715
      Value: Single-phase
    13. Create: Peculiarities #3370716
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, external control connector, thermometer, water filter
    14. Create: Expansion tank volume #3370717
      Value: 7 l
    15. Create: Equipment #3370718
      Value: Display
    16. Create: Fuel #3370719
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3370720
      Value: 2.7 cu. m/hour
    18. Create: LPG consumption #3370721
      Value: 2.01 kg/h
    19. Create: Nominal pressure of natural gas #3370722
      Value: 17 - 25 mbar
    20. Create: Permissible LPG pressure #3370723
      Value: 45 mbar
    21. Create: Heat carrier temperature #3370724
      Value: 38 - 85 °С
    22. Create: Temperature in the DHW circuit #3370725
      Value: 35 - 60 °С
    23. Create: Hot water capacity at t 25°C #3370726
      Value: 15.2 l/min
    24. Create: Hot water capacity at t 30°C #3370727
      Value: 12.3 l/min
    25. Create: Max. water pressure in the DHW circuit #3370728
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3370729
      Value: 3 bar
    27. Create: Gas connection #3370730
      Value: 3/4"
    28. Create: Heating circuit connection #3370731
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3370732
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3370733
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3370734
      Value: Yes
    32. Create: Dimensions WxHxD #3370735
      Value: 400x703x325 mm
    33. Create: Weight #3370736
      Value: 32.7 kg
    34. Create: Image #6315657
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id7457326602181501622.jpeg/orig
    35. Create: Preview image #6315658
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id7457326602181501622.jpeg/orig
  2. Donny Darko 30 April 2023 08:14:54
    Name: Gas BIASI RINNOVA M290.24CM/M; Catalog: Heating boilers