Change history for item: Gas Buderus Logamax U052-28T 28 kW double-circuit

  1. Donny Darko 07 July 2023 17:45:39
    1. Create: Description #3368586
      Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3368587
      Value: Gas, convection
    3. Create: Burner #3368588
      Value: Gas
    4. Create: Number of circuits #3368589
      Value: Double-circuit
    5. Create: Thermal power #3368590
      Value: 10 - 28 kW
    6. Create: The combustion chamber #3368591
      Value: Closed
    7. Create: Efficiency #3368592
      Value: 93.6 %
    8. Create: Control #3368593
      Value: Electronic
    9. Create: Installation #3368594
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3368595
      Value: Copper
    11. Create: Mains voltage #3368596
      Value: Single-phase
    12. Create: Peculiarities #3368597
      Value: Air vent, built-in expansion tank, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3368598
      Value: 48 l
    14. Create: Expansion tank volume #3368599
      Value: 7.5 l
    15. Create: Equipment #3368600
      Value: Built-in boiler, display
    16. Create: Fuel #3368601
      Value: Natural gas, liquefied gas
    17. Create: Nominal pressure of natural gas #3368602
      Value: 13 - 20 mbar
    18. Create: Permissible LPG pressure #3368603
      Value: 37 mbar
    19. Create: Heat carrier temperature #3368604
      Value: 45 - 90 °С
    20. Create: Temperature in the DHW circuit #3368605
      Value: 40 - 60 °С
    21. Create: Max. water pressure in the DHW circuit #3368606
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3368607
      Value: 3 bar
    23. Create: Gas connection #3368608
      Value: 3/4"
    24. Create: Heating circuit connection #3368609
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3368610
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3368611
      Value: 60/100 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3368612
      Value: Yes
    28. Create: Dimensions WxHxD #3368613
      Value: 600x880x475mm
    29. Create: Weight #3368614
      Value: 79 kg
    30. Create: Additional Information #3368615
      Value: DHW expansion tank volume: 2 liters
    31. Create: Image #6314989
      URL: https://avatars.mds.yandex.net/get-mpic/4737085/img_id6007718129029763929.jpeg/orig
    32. Create: Preview image #6314990
      URL: https://avatars.mds.yandex.net/get-mpic/4737085/img_id6007718129029763929.jpeg/orig
  2. Donny Darko 30 April 2023 08:14:16
    Name: Gas Buderus Logamax U052-28T 28 kW double-circuit; Catalog: Heating boilers