Change history for item: Gas Buderus Logamax U042-24K

  1. Donny Darko 07 July 2023 17:39:46
    1. Create: Description #3366692
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3366693
      Value: Gas, convection
    3. Create: Burner #3366694
      Value: Gas
    4. Create: Number of circuits #3366695
      Value: Double-circuit
    5. Create: Thermal power #3366696
      Value: 9.30 - 24 kW
    6. Create: Thermal load #3366697
      Value: 10.70 - 26.30 kW
    7. Create: The combustion chamber #3366698
      Value: Closed
    8. Create: Heated area #3366699
      Value: 240 sq.m
    9. Create: Efficiency #3366700
      Value: 97 %
    10. Create: Control #3366701
      Value: Electronic
    11. Create: Installation #3366702
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3366703
      Value: Copper
    13. Create: Mains voltage #3366704
      Value: Single-phase
    14. Create: Peculiarities #3366705
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3366706
      Value: 8 l
    16. Create: Equipment #3366707
      Value: Display
    17. Create: Fuel #3366708
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3366709
      Value: 2.72 cu. m/hour
    19. Create: LPG consumption #3366710
      Value: 1.93 kg/h
    20. Create: Nominal pressure of natural gas #3366711
      Value: 13 mbar
    21. Create: Permissible LPG pressure #3366712
      Value: 37 mbar
    22. Create: Heat carrier temperature #3366713
      Value: 40 - 82 °С
    23. Create: Temperature in the DHW circuit #3366714
      Value: 40 - 60 °С
    24. Create: Hot water capacity at t 25°C #3366715
      Value: 14 l/min
    25. Create: Max. water pressure in the DHW circuit #3366716
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3366717
      Value: 3 bar
    27. Create: Gas connection #3366718
      Value: 3/4"
    28. Create: Heating circuit connection #3366719
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3366720
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3366721
      Value: 60/100 mm
    31. Create: Dimensions WxHxD #3366722
      Value: 400x740x360mm
    32. Create: Weight #3366723
      Value: 37.9 kg
    33. Create: Additional Information #3366724
      Value: Built-in make-up tap
    34. Create: Image #6314596
      URL: https://avatars.mds.yandex.net/get-mpic/1864685/img_id3051221030046205258/orig
    35. Create: Preview image #6314597
      URL: https://avatars.mds.yandex.net/get-mpic/1864685/img_id3051221030046205258/orig
  2. Donny Darko 30 April 2023 08:13:52
    Name: Gas Buderus Logamax U042-24K; Catalog: Heating boilers