Change history for item: Gas Buderus Logamax U032K

  1. Donny Darko 07 July 2023 17:39:37
    1. Create: Description #3366634
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3366635
      Value: Gas, convection
    3. Create: Burner #3366636
      Value: Gas
    4. Create: Number of circuits #3366637
      Value: Double-circuit
    5. Create: Thermal power #3366638
      Value: 7 - 24 kW
    6. Create: Thermal load #3366639
      Value: 8.40 - 26.50 kW
    7. Create: The combustion chamber #3366640
      Value: Closed
    8. Create: Efficiency #3366641
      Value: 92.2 %
    9. Create: Control #3366642
      Value: Electronic
    10. Create: Installation #3366643
      Value: Wall-mounted
    11. Create: Mains voltage #3366644
      Value: Single-phase
    12. Create: Peculiarities #3366645
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
    13. Create: Expansion tank volume #3366646
      Value: 6 l
    14. Create: Equipment #3366647
      Value: Display
    15. Create: Fuel #3366648
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3366649
      Value: 2.8 cu. m/hour
    17. Create: LPG consumption #3366650
      Value: 2.1 kg/hour
    18. Create: Nominal pressure of natural gas #3366651
      Value: 16 mbar
    19. Create: Permissible LPG pressure #3366652
      Value: 37 mbar
    20. Create: Heat carrier temperature #3366653
      Value: 45 - 88 °С
    21. Create: Temperature in the DHW circuit #3366654
      Value: 40 - 60 °С
    22. Create: Max. water pressure in the DHW circuit #3366655
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3366656
      Value: 3 bar
    24. Create: Gas connection #3366657
      Value: 3/4"
    25. Create: Heating circuit connection #3366658
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3366659
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3366660
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3366661
      Value: 400x700x295mm
    29. Create: Weight #3366662
      Value: 33 kg
    30. Create: Image #6314592
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id3133311568038200496/orig
    31. Create: Preview image #6314593
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id3133311568038200496/orig
  2. Donny Darko 30 April 2023 08:13:52
    Name: Gas Buderus Logamax U032K; Catalog: Heating boilers