Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 17:32:43
Create:
Description #3364921
Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3364922
Value: Gas, condensing
Create:
Burner #3364923
Value: Gas
Create:
Number of circuits #3364924
Value: Double-circuit
Create:
Thermal power #3364925
Value: 1.60 - 35 kW
Create:
Thermal load #3364926
Value: 1.70 - 34.90 kW
Create:
The combustion chamber #3364927
Value: Closed
Create:
Heated area #3364928
Value: 260 sq.m
Create:
Efficiency #3364929
Value: 109 %
Create:
Control #3364930
Value: Electronic
Create:
Installation #3364931
Value: Wall-mounted
Create:
Primary heat exchanger material #3364932
Value: Stainless steel
Create:
Mains voltage #3364933
Value: Single-phase
Create:
Peculiarities #3364934
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3364935
Value: 10 l
Create:
Equipment #3364936
Value: Display
Create:
Fuel #3364937
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3364938
Value: 3.69 cu. m/hour
Create:
LPG consumption #3364939
Value: 2.73 kg/h
Create:
Nominal pressure of natural gas #3364940
Value: 20 mbar
Create:
Permissible LPG pressure #3364941
Value: 50 mbar
Create:
Heat carrier temperature #3364942
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3364943
Value: 30 - 57 °С
Create:
Hot water capacity at t 30°C #3364944
Value: 16.7 l/min
Create:
Max. water pressure in the DHW circuit #3364945
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3364946
Value: 3 bar
Create:
Gas connection #3364947
Value: 1/2"
Create:
Heating circuit connection #3364948
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3364949
Value: 1/2"
Create:
Coaxial chimney diameter #3364950
Value: 60/100 mm
Create:
Dimensions WxHxD #3364951
Value: 450x800x375 mm
Create:
Weight #3364952
Value: 45 kg
Create:
Additional Information #3364953
Value: Weather-compensated Vitotronic 200 type HO2B
Create:
Image #6313969
URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id3145955856651756248.jpeg/orig
Create:
Image #6313970
URL: https://avatars.mds.yandex.net/get-mpic/5425309/img_id8188549978022798964.jpeg/orig
Create:
Image #6313971
URL: https://avatars.mds.yandex.net/get-mpic/4334326/img_id6605227444986171827.jpeg/orig
Create:
Preview image #6313972
URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id3145955856651756248.jpeg/orig
Donny Darko 30 April 2023 08:13:21
Name: Gas Viessmann Vitodens 200-W B2KB066; Catalog: Heating boilers