Description #3364887
Value: Type of heating boiler: gas, max. thermal power: 26 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3364888
Value: Gas, condensing
Create:
Burner #3364889
Value: Gas
Create:
Number of circuits #3364890
Value: Double-circuit
Create:
Thermal power #3364891
Value: 2.40 - 26 kW
Create:
Thermal load #3364892
Value: 2.50 - 30.50 kW
Create:
The combustion chamber #3364893
Value: Closed
Create:
Heated area #3364894
Value: 260 sq.m
Create:
Efficiency #3364895
Value: 109 %
Create:
Control #3364896
Value: Electronic
Create:
Installation #3364897
Value: Wall-mounted
Create:
Primary heat exchanger material #3364898
Value: Stainless steel
Create:
Mains voltage #3364899
Value: Single-phase
Create:
Peculiarities #3364900
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3364901
Value: 10 l
Create:
Equipment #3364902
Value: Display
Create:
Fuel #3364903
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3364904
Value: 3.23 cu. m/hour
Create:
LPG consumption #3364905
Value: 2.38 kg/h
Create:
Nominal pressure of natural gas #3364906
Value: 20 mbar
Create:
Permissible LPG pressure #3364907
Value: 50 mbar
Create:
Heat carrier temperature #3364908
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3364909
Value: 30 - 57 °С
Create:
Hot water capacity at t 30°C #3364910
Value: 13.9 l/min
Create:
Hot water capacity at t 35°C #3364911
Value: 12 l/min
Create:
Max. water pressure in the DHW circuit #3364912
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3364913
Value: 3 bar
Create:
Gas connection #3364914
Value: 1/2"
Create:
Heating circuit connection #3364915
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3364916
Value: 1/2"
Create:
Coaxial chimney diameter #3364917
Value: 60/100 mm
Create:
Dimensions WxHxD #3364918
Value: 450x800x375 mm
Create:
Weight #3364919
Value: 40 kg
Create:
Additional Information #3364920
Value: Weather-compensated Vitotronic 200 type HO2B
Create:
Image #6313965
URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id132667602687401915.jpeg/orig
Create:
Image #6313966
URL: https://avatars.mds.yandex.net/get-mpic/5425309/img_id8188549978022798964.jpeg/orig
Create:
Image #6313967
URL: https://avatars.mds.yandex.net/get-mpic/4334326/img_id6605227444986171827.jpeg/orig
Create:
Preview image #6313968
URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id132667602687401915.jpeg/orig
Donny Darko 30 April 2023 08:13:21
Name: Gas Viessmann Vitodens 200-W B2KB065; Catalog: Heating boilers