Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 17:32:35
Create:
Description #3364854
Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3364855
Value: Gas, condensing
Create:
Burner #3364856
Value: Gas
Create:
Number of circuits #3364857
Value: Double-circuit
Create:
Thermal power #3364858
Value: 1.60 - 35 kW
Create:
Thermal load #3364859
Value: 1.70 - 34.90 kW
Create:
The combustion chamber #3364860
Value: Closed
Create:
Heated area #3364861
Value: 260 sq.m
Create:
Efficiency #3364862
Value: 109 %
Create:
Control #3364863
Value: Electronic
Create:
Installation #3364864
Value: Wall-mounted
Create:
Primary heat exchanger material #3364865
Value: Stainless steel
Create:
Mains voltage #3364866
Value: Single-phase
Create:
Peculiarities #3364867
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3364868
Value: 10 l
Create:
Equipment #3364869
Value: Display
Create:
Fuel #3364870
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3364871
Value: 3.69 cu. m/hour
Create:
LPG consumption #3364872
Value: 2.73 kg/h
Create:
Nominal pressure of natural gas #3364873
Value: 20 mbar
Create:
Permissible LPG pressure #3364874
Value: 50 mbar
Create:
Heat carrier temperature #3364875
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3364876
Value: 30 - 57 °С
Create:
Hot water capacity at t 30°C #3364877
Value: 16.7 l/min
Create:
Max. water pressure in the DHW circuit #3364878
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3364879
Value: 3 bar
Create:
Gas connection #3364880
Value: 1/2"
Create:
Heating circuit connection #3364881
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3364882
Value: 1/2"
Create:
Coaxial chimney diameter #3364883
Value: 60/100 mm
Create:
Dimensions WxHxD #3364884
Value: 450x800x375 mm
Create:
Weight #3364885
Value: 45 kg
Create:
Additional Information #3364886
Value: Vitotronic 100 type HC1B
Create:
Image #6313962
URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id6796182428447827487.jpeg/orig
Create:
Image #6313963
URL: https://avatars.mds.yandex.net/get-mpic/5280669/img_id2690347873665499725.jpeg/orig
Create:
Preview image #6313964
URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id6796182428447827487.jpeg/orig
Donny Darko 30 April 2023 08:13:20
Name: Gas Viessmann Vitodens 200-W B2KB064; Catalog: Heating boilers