Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 17:32:29
Create:
Description #3364820
Value: Type of heating boiler: gas, max. thermal power: 26 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3364821
Value: Gas, condensing
Create:
Burner #3364822
Value: Gas
Create:
Number of circuits #3364823
Value: Double-circuit
Create:
Thermal power #3364824
Value: 2.40 - 26 kW
Create:
Thermal load #3364825
Value: 2.50 - 30.50 kW
Create:
The combustion chamber #3364826
Value: Closed
Create:
Heated area #3364827
Value: 260 sq.m
Create:
Efficiency #3364828
Value: 109 %
Create:
Control #3364829
Value: Electronic
Create:
Installation #3364830
Value: Wall-mounted
Create:
Primary heat exchanger material #3364831
Value: Stainless steel
Create:
Mains voltage #3364832
Value: Single-phase
Create:
Peculiarities #3364833
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3364834
Value: 10 l
Create:
Equipment #3364835
Value: Display
Create:
Fuel #3364836
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3364837
Value: 3.23 cu. m/hour
Create:
LPG consumption #3364838
Value: 2.38 kg/h
Create:
Nominal pressure of natural gas #3364839
Value: 20 mbar
Create:
Permissible LPG pressure #3364840
Value: 50 mbar
Create:
Heat carrier temperature #3364841
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3364842
Value: 30 - 57 °С
Create:
Hot water capacity at t 30°C #3364843
Value: 13.9 l/min
Create:
Hot water capacity at t 35°C #3364844
Value: 12 l/min
Create:
Max. water pressure in the DHW circuit #3364845
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3364846
Value: 3 bar
Create:
Gas connection #3364847
Value: 1/2"
Create:
Heating circuit connection #3364848
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3364849
Value: 1/2"
Create:
Coaxial chimney diameter #3364850
Value: 60/100 mm
Create:
Dimensions WxHxD #3364851
Value: 450x800x375 mm
Create:
Weight #3364852
Value: 40 kg
Create:
Additional Information #3364853
Value: Vitotronic 100 type HC1B
Create:
Image #6313959
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id5998581503457381715.jpeg/orig
Create:
Image #6313960
URL: https://avatars.mds.yandex.net/get-mpic/5280669/img_id2690347873665499725.jpeg/orig
Create:
Preview image #6313961
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id5998581503457381715.jpeg/orig
Donny Darko 30 April 2023 08:13:20
Name: Gas Viessmann Vitodens 200-W B2KB063; Catalog: Heating boilers