Change history for item: Gas Viessmann Vitopend 100-W WH1D516 31 kW double-circuit

  1. Donny Darko 07 July 2023 17:30:15
    1. Create: Description #3364003
      Value: Type of heating boiler: gas, max. thermal power: 31 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3364004
      Value: Gas, convection
    3. Create: Burner #3364005
      Value: Gas
    4. Create: Number of circuits #3364006
      Value: Double-circuit
    5. Create: Thermal power #3364007
      Value: 13.20 - 31 kW
    6. Create: Thermal load #3364008
      Value: 14.50 - 33.30 kW
    7. Create: The combustion chamber #3364009
      Value: Closed
    8. Create: Efficiency #3364010
      Value: 93 %
    9. Create: Control #3364011
      Value: Electronic
    10. Create: Installation #3364012
      Value: Wall-mounted
    11. Create: Mains voltage #3364013
      Value: Single-phase
    12. Create: Peculiarities #3364014
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3364015
      Value: 10 l
    14. Create: Equipment #3364016
      Value: Display
    15. Create: Fuel #3364017
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3364018
      Value: 3.53 cu. m/hour
    17. Create: LPG consumption #3364019
      Value: 2.61 kg/hour
    18. Create: Nominal pressure of natural gas #3364020
      Value: 13 - 30 mbar
    19. Create: Permissible LPG pressure #3364021
      Value: 57.5 mbar
    20. Create: Heat carrier temperature #3364022
      Value: 40 - 76 °С
    21. Create: Temperature in the DHW circuit #3364023
      Value: 30 - 57 °С
    22. Create: Hot water capacity at t 30°C #3364024
      Value: 14.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3364025
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3364026
      Value: 3 bar
    25. Create: Gas connection #3364027
      Value: 3/4"
    26. Create: Heating circuit connection #3364028
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3364029
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3364030
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3364031
      Value: Yes
    30. Create: Dimensions WxHxD #3364032
      Value: 450x725x340 mm
    31. Create: Weight #3364033
      Value: 39 kg
    32. Create: Image #6313831
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id3449212128560600171/orig
    33. Create: Preview image #6313832
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id3449212128560600171/orig
  2. Donny Darko 30 April 2023 08:13:11
    Name: Gas Viessmann Vitopend 100-W WH1D516 31 kW double-circuit; Catalog: Heating boilers