- Donny Darko 07 July 2023 17:29:20
-
Create:
Description #3363660
Value: Boiler type: gas, number of circuits: two-circuit, max. heat output: 31 kW, heated area: 310 m², placement: wall-mounted, electrical network type: single-phase, combustion chamber type: closed,
-
Create:
Type of heating boiler #3363661
Value: Gas, convection
-
Create:
Burner #3363662
Value: Gas
-
Create:
Number of circuits #3363663
Value: Double-circuit
-
Create:
Thermal power #3363664
Value: 13.20 - 31 kW
-
Create:
Thermal load #3363665
Value: 14.50 - 33.30 kW
-
Create:
The combustion chamber #3363666
Value: Closed
-
Create:
Heated area #3363667
Value: 310 sq.m
-
Create:
Efficiency #3363668
Value: 93 %
-
Create:
Control #3363669
Value: Electronic
-
Create:
Installation #3363670
Value: Wall-mounted
-
Create:
Mains voltage #3363671
Value: Single-phase
-
Create:
Built-in circulation pump #3363672
Value: There is
-
Create:
Built-in expansion tank #3363673
Value: There is
-
Create:
Expansion tank volume #3363674
Value: 10 l
-
Create:
Equipment #3363675
Value: Display
-
Create:
Fuel #3363676
Value: Natural gas, liquefied gas
-
Create:
Natural gas consumption #3363677
Value: 3.53 cu. m/hour
-
Create:
LPG consumption #3363678
Value: 2.61 kg/hour
-
Create:
Nominal pressure of natural gas #3363679
Value: 20 - 30 mbar
-
Create:
Permissible LPG pressure #3363680
Value: 57.5 mbar
-
Create:
Heat carrier temperature #3363681
Value: 40 - 76 °С
-
Create:
Temperature in the DHW circuit #3363682
Value: 30 - 57 °С
-
Create:
Hot water capacity at t 30°C #3363683
Value: 14.3 l/min
-
Create:
Max. water pressure in the DHW circuit #3363684
Value: 10 bar
-
Create:
Max. water pressure in the heating circuit #3363685
Value: 3 bar
-
Create:
Functions #3363686
Value: Frost protection, thermometer, manometer
-
Create:
Peculiarities #3363687
Value: External control connection
-
Create:
Protection #3363688
Value: Gas control, safety valve, air vent
-
Create:
Gas connection #3363689
Value: 3/4"
-
Create:
Heating circuit connection #3363690
Value: 3/4"
-
Create:
Branch pipe for connecting the DHW circuit #3363691
Value: 1/2"
-
Create:
Coaxial chimney diameter #3363692
Value: 60/100 mm
-
Create:
Connection of a separate chimney diameter 80 mm #3363693
Value: Yes
-
Create:
Dimensions WxHxD #3363694
Value: 450x725x360 mm
-
Create:
Weight #3363695
Value: 39 kg
-
Create:
Image #6313803
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5372691633787582709/orig
-
Create:
Preview image #6313804
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5372691633787582709/orig
- Donny Darko 30 April 2023 08:13:07
Name: Gas Viessmann Vitopend 100-W WH1B024 31 kW double-circuit; Catalog: Heating boilers