Change history for item: Gas Viessmann Vitodens 200-W B2KA039 26 kW double-circuit

  1. Donny Darko 07 July 2023 17:20:14
    1. Create: Description #3360472
      Value: Type of heating boiler: gas, max. thermal power: 26 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3360473
      Value: Gas, condensing
    3. Create: Burner #3360474
      Value: Gas
    4. Create: Number of circuits #3360475
      Value: Double-circuit
    5. Create: Thermal power #3360476
      Value: 4.70 - 26 kW
    6. Create: The combustion chamber #3360477
      Value: Closed
    7. Create: Efficiency #3360478
      Value: 109 %
    8. Create: Control #3360479
      Value: Electronic
    9. Create: Installation #3360480
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3360481
      Value: Stainless steel
    11. Create: Mains voltage #3360482
      Value: Single-phase
    12. Create: Peculiarities #3360483
      Value: Built-in expansion tank, safety valve, thermometer
    13. Create: Expansion tank volume #3360484
      Value: 10 l
    14. Create: Equipment #3360485
      Value: Outdoor temperature sensor, display
    15. Create: Fuel #3360486
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3360487
      Value: 3.75 cu. m/hour
    17. Create: LPG consumption #3360488
      Value: 2.38 kg/h
    18. Create: Nominal pressure of natural gas #3360489
      Value: 25 mbar
    19. Create: Permissible LPG pressure #3360490
      Value: 57.5 mbar
    20. Create: Heat carrier temperature #3360491
      Value: 30 - 80 °С
    21. Create: Temperature in the DHW circuit #3360492
      Value: 30 - 57 °С
    22. Create: Hot water capacity at t 30°C #3360493
      Value: 13.9 l/min
    23. Create: Max. water pressure in the DHW circuit #3360494
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3360495
      Value: 3 bar
    25. Create: Gas connection #3360496
      Value: 1/2"
    26. Create: Branch pipe for connecting the DHW circuit #3360497
      Value: 1/2"
    27. Create: Dimensions WxHxD #3360498
      Value: 450x850x360 mm
    28. Create: Weight #3360499
      Value: 46 kg
    29. Create: Additional Information #3360500
      Value: Vitotronic 200 controller, type HO1B
    30. Create: Image #6313530
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id393641663866927823.jpeg/orig
    31. Create: Preview image #6313531
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id393641663866927823.jpeg/orig
  2. Donny Darko 30 April 2023 08:12:26
    Name: Gas Viessmann Vitodens 200-W B2KA039 26 kW double-circuit; Catalog: Heating boilers