Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 17:04:34
Create:
Description #3356117
Value: Type of heating boiler: gas, max. heating power: 24.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3356118
Value: Gas, convection
Create:
Burner #3356119
Value: Gas
Create:
Number of circuits #3356120
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3356121
Value: 10.70 - 24.80 kW
Create:
Thermal load #3356122
Value: 11.70 - 26.70 kW
Create:
The combustion chamber #3356123
Value: Closed
Create:
Efficiency #3356124
Value: 92.8 %
Create:
Control #3356125
Value: Electronic
Create:
Installation #3356126
Value: Wall-mounted
Create:
Mains voltage #3356127
Value: Single-phase
Create:
Peculiarities #3356128
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3356129
Value: 6 l
Create:
Equipment #3356130
Value: Display
Create:
Fuel #3356131
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3356132
Value: 2.83 cu. m/hour
Create:
LPG consumption #3356133
Value: 2.09 kg/h
Create:
Nominal pressure of natural gas #3356134
Value: 13 - 30 mbar
Create:
Permissible LPG pressure #3356135
Value: 57.5 mbar
Create:
Max. coolant temperature #3356136
Value: 76 °С
Create:
Temperature in the DHW circuit #3356137
Value: 30 - 57 °С
Create:
Hot water capacity at t 30°C #3356138
Value: 11.5 l/min
Create:
Max. water pressure in the DHW circuit #3356139
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3356140
Value: 3 bar
Create:
Gas connection #3356141
Value: 3/4"
Create:
Heating circuit connection #3356142
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3356143
Value: 1/2"
Create:
Coaxial chimney diameter #3356144
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3356145
Value: Yes
Create:
Dimensions WxHxD #3356146
Value: 400x725x340mm
Create:
Weight #3356147
Value: 36 kg
Create:
Additional Information #3356148
Value: Complete with: spigot for connecting a coaxial exhaust system, mounting device with shut-off valves
Create:
Image #6313120
URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id6891324035749560680/orig
Create:
Preview image #6313121
URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id6891324035749560680/orig
Donny Darko 30 April 2023 08:11:31
Name: Gas Viessmann Vitopend 100-W WH1D266; Catalog: Heating boilers