Change history for item: Gas Viessmann Vitopend 100-W WH1D263

  1. Donny Darko 07 July 2023 17:04:23
    1. Create: Description #3356021
      Value: Type of heating boiler: gas, max. heating power: 31.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3356022
      Value: Gas, convection
    3. Create: Burner #3356023
      Value: Gas
    4. Create: Number of circuits #3356024
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3356025
      Value: 13.20 - 31.20 kW
    6. Create: Thermal load #3356026
      Value: 14.50 - 33.30 kW
    7. Create: The combustion chamber #3356027
      Value: Closed
    8. Create: Efficiency #3356028
      Value: 93 %
    9. Create: Control #3356029
      Value: Electronic
    10. Create: Installation #3356030
      Value: Wall-mounted
    11. Create: Mains voltage #3356031
      Value: Single-phase
    12. Create: Peculiarities #3356032
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3356033
      Value: 10 l
    14. Create: Equipment #3356034
      Value: Display
    15. Create: Fuel #3356035
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3356036
      Value: 3.53 cu. m/hour
    17. Create: LPG consumption #3356037
      Value: 2.61 kg/hour
    18. Create: Nominal pressure of natural gas #3356038
      Value: 13 - 30 mbar
    19. Create: Permissible LPG pressure #3356039
      Value: 57.5 mbar
    20. Create: Max. coolant temperature #3356040
      Value: 76 °С
    21. Create: Temperature in the DHW circuit #3356041
      Value: 30 - 57 °С
    22. Create: Hot water capacity at t 30°C #3356042
      Value: 14.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3356043
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3356044
      Value: 3 bar
    25. Create: Gas connection #3356045
      Value: 3/4"
    26. Create: Heating circuit connection #3356046
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3356047
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3356048
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3356049
      Value: Yes
    30. Create: Dimensions WxHxD #3356050
      Value: 450x725x360 mm
    31. Create: Weight #3356051
      Value: 39 kg
    32. Create: Additional Information #3356052
      Value: Complete with: pipe for connecting a coaxial system for removing combustion products
    33. Create: Image #6313114
      URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id6891324035749560680/orig
    34. Create: Preview image #6313115
      URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id6891324035749560680/orig
  2. Donny Darko 30 April 2023 08:11:31
    Name: Gas Viessmann Vitopend 100-W WH1D263; Catalog: Heating boilers