Change history for item: Gas Vaillant turboTEC pro VUW 242/3-3M 24 kW double-circuit

  1. Donny Darko 07 July 2023 16:38:58
    1. Create: Description #3350574
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3350575
      Value: Gas, convection
    3. Create: Burner #3350576
      Value: Gas
    4. Create: Number of circuits #3350577
      Value: Double-circuit
    5. Create: Thermal power #3350578
      Value: 9.60 - 24 kW
    6. Create: Thermal load #3350579
      Value: 10.70 - 26.70 kW
    7. Create: The combustion chamber #3350580
      Value: Closed
    8. Create: Control #3350581
      Value: Electronic
    9. Create: Installation #3350582
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3350583
      Value: Copper
    11. Create: Mains voltage #3350584
      Value: Single-phase
    12. Create: Peculiarities #3350585
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3350586
      Value: 10 l
    14. Create: Equipment #3350587
      Value: Display
    15. Create: Fuel #3350588
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3350589
      Value: 2.8 cu. m/hour
    17. Create: LPG consumption #3350590
      Value: 2.1 kg/hour
    18. Create: Nominal pressure of natural gas #3350591
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3350592
      Value: 30 mbar
    20. Create: Heat carrier temperature #3350593
      Value: 30 - 85 °С
    21. Create: Temperature in the DHW circuit #3350594
      Value: 35 - 65 °С
    22. Create: Hot water capacity at t 30°C #3350595
      Value: 11.5 l/min
    23. Create: Hot water capacity at t 45°C #3350596
      Value: 7.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3350597
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3350598
      Value: 3 bar
    26. Create: Gas connection #3350599
      Value: 3/4"
    27. Create: Heating circuit connection #3350600
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3350601
      Value: 3/4"
    29. Create: Coaxial chimney diameter #3350602
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3350603
      Value: 410x700x300mm
    31. Create: Weight #3350604
      Value: 32 kg
    32. Create: Image #6311497
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1913839957419416029/orig
    33. Create: Preview image #6311498
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1913839957419416029/orig
  2. Donny Darko 30 April 2023 08:09:50
    Name: Gas Vaillant turboTEC pro VUW 242/3-3M 24 kW double-circuit; Catalog: Heating boilers