Change history for item: Gas Vaillant atmoCRAFT VK INT 654/9

  1. Donny Darko 07 July 2023 16:38:05
    1. Create: Description #3350260
      Value: Type of heating boiler: gas, max. thermal power: 65 kW, number of circuits: single-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3350261
      Value: Gas, convection
    3. Create: Burner #3350262
      Value: Gas
    4. Create: Number of circuits #3350263
      Value: Single-loop
    5. Create: Max. thermal power #3350264
      Value: 65 kW
    6. Create: Max. thermal load #3350265
      Value: 70.70 kW
    7. Create: The combustion chamber #3350266
      Value: Open
    8. Create: Efficiency #3350267
      Value: 92 %
    9. Create: Control #3350268
      Value: Electronic
    10. Create: Installation #3350269
      Value: Floor
    11. Create: Primary heat exchanger material #3350270
      Value: Cast iron
    12. Create: Power steps #3350271
      Value: 2
    13. Create: Mains voltage #3350272
      Value: Single-phase
    14. Create: Peculiarities #3350273
      Value: Pressure gauge, external control connector, thermometer
    15. Create: Equipment #3350274
      Value: Display
    16. Create: Fuel #3350275
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3350276
      Value: 7.4 cu. m/hour
    18. Create: LPG consumption #3350277
      Value: 5.5 kg/hour
    19. Create: Nominal pressure of natural gas #3350278
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3350279
      Value: 30 mbar
    21. Create: Heat carrier temperature #3350280
      Value: 35 - 83 °С
    22. Create: Max. water pressure in the heating circuit #3350281
      Value: 3 bar
    23. Create: Gas connection #3350282
      Value: 1"
    24. Create: Heating circuit connection #3350283
      Value: 1¼
    25. Create: Chimney diameter #3350284
      Value: 180 mm
    26. Create: Dimensions WxHxD #3350285
      Value: 850x1145x960 mm
    27. Create: Weight #3350286
      Value: 31.7 kg
    28. Create: Additional Information #3350287
      Value: 8 heat exchanger sections
    29. Create: Image #6311442
      URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id7452863589184259277.jpeg/orig
    30. Create: Image #6311443
      URL: https://avatars.mds.yandex.net/get-mpic/4466428/img_id3674082373725819240.jpeg/orig
    31. Create: Image #6311444
      URL: https://avatars.mds.yandex.net/get-mpic/1985106/img_id8031779180277833143.jpeg/orig
    32. Create: Image #6311445
      URL: https://avatars.mds.yandex.net/get-mpic/5235967/img_id3138761136676798748.jpeg/orig
    33. Create: Image #6311446
      URL: https://avatars.mds.yandex.net/get-mpic/5218923/img_id3518703622153244181.jpeg/orig
    34. Create: Image #6311447
      URL: https://avatars.mds.yandex.net/get-mpic/1927699/img_id7929428343910703700.jpeg/orig
    35. Create: Image #6311448
      URL: https://avatars.mds.yandex.net/get-mpic/4709279/img_id7329453312557584389.png/orig
    36. Create: Image #6311449
      URL: https://avatars.mds.yandex.net/get-mpic/5323566/img_id1874830678401263467.jpeg/orig
    37. Create: Preview image #6311450
      URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id7452863589184259277.jpeg/orig
  2. Donny Darko 30 April 2023 08:09:47
    Name: Gas Vaillant atmoCRAFT VK INT 654/9; Catalog: Heating boilers