Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 16:38:02
Create:
Description #3350227
Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3350228
Value: Gas, condensing
Create:
Burner #3350229
Value: Gas
Create:
Number of circuits #3350230
Value: Double-circuit
Create:
Thermal power #3350231
Value: 5.80 - 30 kW
Create:
Thermal load #3350232
Value: 6.20 - 30.60 kW
Create:
The combustion chamber #3350233
Value: Closed
Create:
Efficiency #3350234
Value: 106.2 %
Create:
Control #3350235
Value: Electronic
Create:
Installation #3350236
Value: Floor
Create:
Primary heat exchanger material #3350237
Value: Stainless steel
Create:
Secondary heat exchanger material #3350238
Value: Stainless steel
Create:
Mains voltage #3350239
Value: Single-phase
Create:
Peculiarities #3350240
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, connector for external control, thermometer
Create:
The volume of the built-in boiler #3350241
Value: 150 l
Create:
Expansion tank volume #3350242
Value: 12 l
Create:
Equipment #3350243
Value: Built-in boiler, display
Create:
Fuel #3350244
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3350245
Value: 3.67 cu. m/hour
Create:
Nominal pressure of natural gas #3350246
Value: 13 - 20 mbar
Create:
Heat carrier temperature #3350247
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3350248
Value: 35 - 65 °С
Create:
Hot water capacity at t 20°C #3350249
Value: 21.53 l/min
Create:
Hot water capacity at t 30°C #3350250
Value: 14 l/min
Create:
Max. water pressure in the DHW circuit #3350251
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3350252
Value: 3 bar
Create:
Gas connection #3350253
Value: 3/4"
Create:
Heating circuit connection #3350254
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3350255
Value: 3/4"
Create:
Coaxial chimney diameter #3350256
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3350257
Value: Yes
Create:
Dimensions WxHxD #3350258
Value: 599x1640x693 mm
Create:
Weight #3350259
Value: 128 kg
Create:
Image #6311440
URL: https://avatars.mds.yandex.net/get-mpic/4947485/img_id7938309347998015036.jpeg/orig
Create:
Preview image #6311441
URL: https://avatars.mds.yandex.net/get-mpic/4947485/img_id7938309347998015036.jpeg/orig
Donny Darko 30 April 2023 08:09:47
Name: Gas Vaillant ecoCOMPACT VSC 306/4-5 150; Catalog: Heating boilers