Change history for item: Gas Vaillant ecoTEC plus VUW OE 296

  1. Donny Darko 07 July 2023 16:37:37
    1. Create: Description #3350037
      Value: Type of heating boiler: gas, max. thermal power: 29 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3350038
      Value: Gas, condensing
    3. Create: Burner #3350039
      Value: Gas
    4. Create: Number of circuits #3350040
      Value: Double-circuit
    5. Create: Max. thermal power #3350041
      Value: 29 kW
    6. Create: The combustion chamber #3350042
      Value: Closed
    7. Create: Efficiency #3350043
      Value: 109 %
    8. Create: Control #3350044
      Value: Electronic
    9. Create: Installation #3350045
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3350046
      Value: Stainless steel
    11. Create: Mains voltage #3350047
      Value: Single-phase
    12. Create: Peculiarities #3350048
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3350049
      Value: 10 l
    14. Create: Equipment #3350050
      Value: Display
    15. Create: Fuel #3350051
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3350052
      Value: 3.1 cu. m/hour
    17. Create: LPG consumption #3350053
      Value: 2.3 kg/hour
    18. Create: Nominal pressure of natural gas #3350054
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3350055
      Value: 30 mbar
    20. Create: Heat carrier temperature #3350056
      Value: 40 - 85 °С
    21. Create: Temperature in the DHW circuit #3350057
      Value: 35 - 65 °С
    22. Create: Hot water capacity at t 30°C #3350058
      Value: 13.9 l/min
    23. Create: Hot water capacity at t 35°C #3350059
      Value: 11.9 l/min
    24. Create: Max. water pressure in the DHW circuit #3350060
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3350061
      Value: 3 bar
    26. Create: Gas connection #3350062
      Value: 1/2"
    27. Create: Heating circuit connection #3350063
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3350064
      Value: 3/4"
    29. Create: Coaxial chimney diameter #3350065
      Value: 60/100 mm and 80/125 mm
    30. Create: Dimensions WxHxD #3350066
      Value: 440x720x335 mm
    31. Create: Weight #3350067
      Value: 39 kg
    32. Create: Image #6311422
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5128253741090668901/orig
    33. Create: Preview image #6311423
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id5128253741090668901/orig
  2. Donny Darko 30 April 2023 08:09:45
    Name: Gas Vaillant ecoTEC plus VUW OE 296; Catalog: Heating boilers