Create:
Description #3349892
Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3349893
Value: Gas, condensing
Create:
Burner #3349894
Value: Gas
Create:
Number of circuits #3349895
Value: Double-circuit
Create:
Thermal power #3349896
Value: 5.20 - 25 kW
Create:
Thermal load #3349897
Value: 5.50 - 25.50 kW
Create:
The combustion chamber #3349898
Value: Closed
Create:
Efficiency #3349899
Value: 109 %
Create:
Control #3349900
Value: Electronic
Create:
Installation #3349901
Value: Wall-mounted
Create:
Primary heat exchanger material #3349902
Value: Stainless steel
Create:
Secondary heat exchanger material #3349903
Value: Stainless steel
Create:
Mains voltage #3349904
Value: Single-phase
Create:
Peculiarities #3349905
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3349906
Value: 10 l
Create:
Equipment #3349907
Value: Display
Create:
Fuel #3349908
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3349909
Value: 3.2 cu. m/hour
Create:
LPG consumption #3349910
Value: 2.4 kg/hour
Create:
Nominal pressure of natural gas #3349911
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3349912
Value: 30 mbar
Create:
Heat carrier temperature #3349913
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3349914
Value: 35 - 65 °С
Create:
Hot water capacity at t 30°C #3349915
Value: 14.4 l/min
Create:
Max. water pressure in the DHW circuit #3349916
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3349917
Value: 3 bar
Create:
Gas connection #3349918
Value: 1/2"
Create:
Heating circuit connection #3349919
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3349920
Value: 3/4"
Create:
Coaxial chimney diameter #3349921
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3349922
Value: Yes
Create:
Dimensions WxHxD #3349923
Value: 440x720x338 mm
Create:
Weight #3349924
Value: 363 kg
Create:
Additional Information #3349925
Value: Crimp adapter for gas connection 1/2 -> 3/4 included
Create:
Image #6311406
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id9019643791074671473.jpeg/orig
Create:
Image #6311407
URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id3789485167262296147.jpeg/orig
Create:
Image #6311408
URL: https://avatars.mds.yandex.net/get-mpic/4034173/img_id530811732117243005.jpeg/orig
Create:
Image #6311409
URL: https://avatars.mds.yandex.net/get-mpic/4370207/img_id4138206006881937305.jpeg/orig
Create:
Image #6311410
URL: https://avatars.mds.yandex.net/get-mpic/5236458/img_id7003333358719067408.png/orig
Create:
Image #6311411
URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id3178934152663987219.png/orig
Create:
Image #6311412
URL: https://avatars.mds.yandex.net/get-mpic/1522540/img_id7828430092270980716.png/orig
Create:
Preview image #6311413
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id9019643791074671473.jpeg/orig
Donny Darko 30 April 2023 08:09:43
Name: Gas Vaillant ecoTEC plus VUW INT IV 306/5-5; Catalog: Heating boilers