Change history for item: Gas Vaillant ecoTEC plus VUW INT IV 306/5-5

  1. Donny Darko 07 July 2023 16:37:17
    1. Create: Description #3349892
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3349893
      Value: Gas, condensing
    3. Create: Burner #3349894
      Value: Gas
    4. Create: Number of circuits #3349895
      Value: Double-circuit
    5. Create: Thermal power #3349896
      Value: 5.20 - 25 kW
    6. Create: Thermal load #3349897
      Value: 5.50 - 25.50 kW
    7. Create: The combustion chamber #3349898
      Value: Closed
    8. Create: Efficiency #3349899
      Value: 109 %
    9. Create: Control #3349900
      Value: Electronic
    10. Create: Installation #3349901
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3349902
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3349903
      Value: Stainless steel
    13. Create: Mains voltage #3349904
      Value: Single-phase
    14. Create: Peculiarities #3349905
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3349906
      Value: 10 l
    16. Create: Equipment #3349907
      Value: Display
    17. Create: Fuel #3349908
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3349909
      Value: 3.2 cu. m/hour
    19. Create: LPG consumption #3349910
      Value: 2.4 kg/hour
    20. Create: Nominal pressure of natural gas #3349911
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3349912
      Value: 30 mbar
    22. Create: Heat carrier temperature #3349913
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3349914
      Value: 35 - 65 °С
    24. Create: Hot water capacity at t 30°C #3349915
      Value: 14.4 l/min
    25. Create: Max. water pressure in the DHW circuit #3349916
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3349917
      Value: 3 bar
    27. Create: Gas connection #3349918
      Value: 1/2"
    28. Create: Heating circuit connection #3349919
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3349920
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3349921
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3349922
      Value: Yes
    32. Create: Dimensions WxHxD #3349923
      Value: 440x720x338 mm
    33. Create: Weight #3349924
      Value: 363 kg
    34. Create: Additional Information #3349925
      Value: Crimp adapter for gas connection 1/2 -> 3/4 included
    35. Create: Image #6311406
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id9019643791074671473.jpeg/orig
    36. Create: Image #6311407
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id3789485167262296147.jpeg/orig
    37. Create: Image #6311408
      URL: https://avatars.mds.yandex.net/get-mpic/4034173/img_id530811732117243005.jpeg/orig
    38. Create: Image #6311409
      URL: https://avatars.mds.yandex.net/get-mpic/4370207/img_id4138206006881937305.jpeg/orig
    39. Create: Image #6311410
      URL: https://avatars.mds.yandex.net/get-mpic/5236458/img_id7003333358719067408.png/orig
    40. Create: Image #6311411
      URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id3178934152663987219.png/orig
    41. Create: Image #6311412
      URL: https://avatars.mds.yandex.net/get-mpic/1522540/img_id7828430092270980716.png/orig
    42. Create: Preview image #6311413
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id9019643791074671473.jpeg/orig
  2. Donny Darko 30 April 2023 08:09:43
    Name: Gas Vaillant ecoTEC plus VUW INT IV 306/5-5; Catalog: Heating boilers