Change history for item: Gas Vaillant ecoCOMPACT VSC INT 196 19 kW double-circuit

  1. Donny Darko 07 July 2023 16:36:05
    1. Create: Description #3349488
      Value: Type of heating boiler: gas, max. thermal power: 19 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3349489
      Value: Gas, condensing
    3. Create: Burner #3349490
      Value: Gas
    4. Create: Number of circuits #3349491
      Value: Double-circuit
    5. Create: Thermal power #3349492
      Value: 6.70 - 19 kW
    6. Create: Thermal load #3349493
      Value: 6.80 - 19.40 kW
    7. Create: The combustion chamber #3349494
      Value: Closed
    8. Create: Efficiency #3349495
      Value: 109 %
    9. Create: Control #3349496
      Value: Electronic
    10. Create: Installation #3349497
      Value: Floor
    11. Create: Primary heat exchanger material #3349498
      Value: Stainless steel
    12. Create: Mains voltage #3349499
      Value: Single-phase
    13. Create: Peculiarities #3349500
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3349501
      Value: 100 l
    15. Create: Expansion tank volume #3349502
      Value: 12 l
    16. Create: Equipment #3349503
      Value: Built-in boiler, display
    17. Create: Fuel #3349504
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3349505
      Value: 2.5 cu. m/hour
    19. Create: LPG consumption #3349506
      Value: 1.83 kg/h
    20. Create: Nominal pressure of natural gas #3349507
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3349508
      Value: 30 mbar
    22. Create: Heat carrier temperature #3349509
      Value: 35 - 85 °С
    23. Create: Temperature in the DHW circuit #3349510
      Value: 40 - 60 °С
    24. Create: Max. water pressure in the DHW circuit #3349511
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3349512
      Value: 3 bar
    26. Create: Gas connection #3349513
      Value: 3/4"
    27. Create: Heating circuit connection #3349514
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3349515
      Value: 3/4"
    29. Create: Coaxial chimney diameter #3349516
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3349517
      Value: 600x1350x570 mm
    31. Create: Weight #3349518
      Value: 105 kg
    32. Create: Image #6311212
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2605394289325287218/orig
    33. Create: Preview image #6311213
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2605394289325287218/orig