Donny Darko 07 July 2023 16:35:40
Create:
Description #3349351
Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3349352
Value: Gas, condensing
Create:
Burner #3349353
Value: Gas
Create:
Number of circuits #3349354
Value: Double-circuit
Create:
Thermal power #3349355
Value: 3.80 - 20 kW
Create:
Thermal load #3349356
Value: 4 - 20.40 kW
Create:
The combustion chamber #3349357
Value: Closed
Create:
Efficiency #3349358
Value: 109 %
Create:
Control #3349359
Value: Electronic
Create:
Installation #3349360
Value: Wall-mounted
Create:
Primary heat exchanger material #3349361
Value: Stainless steel
Create:
Secondary heat exchanger material #3349362
Value: Stainless steel
Create:
Mains voltage #3349363
Value: Single-phase
Create:
Peculiarities #3349364
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3349365
Value: 10 l
Create:
Equipment #3349366
Value: Display
Create:
Fuel #3349367
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3349368
Value: 2.6 cu. m/hour
Create:
LPG consumption #3349369
Value: 1.9 kg/hour
Create:
Nominal pressure of natural gas #3349370
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3349371
Value: 30 mbar
Create:
Heat carrier temperature #3349372
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3349373
Value: 35 - 65 °С
Create:
Hot water capacity at t 30°C #3349374
Value: 11.5 l/min
Create:
Max. water pressure in the DHW circuit #3349375
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3349376
Value: 3 bar
Create:
Gas connection #3349377
Value: 1/2"
Create:
Heating circuit connection #3349378
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3349379
Value: 3/4"
Create:
Coaxial chimney diameter #3349380
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3349381
Value: Yes
Create:
Dimensions WxHxD #3349382
Value: 440x720x338 mm
Create:
Weight #3349383
Value: 35 kg
Create:
Additional Information #3349384
Value: Crimp adapter for gas connection 1/2" -> 3/4" included
Create:
Image #6311170
URL: https://avatars.mds.yandex.net/get-mpic/4343038/img_id9188386564745035448.jpeg/orig
Create:
Image #6311171
URL: https://avatars.mds.yandex.net/get-mpic/7979270/img_id1825108660694792074.jpeg/orig
Create:
Image #6311172
URL: https://avatars.mds.yandex.net/get-mpic/2017118/img_id1201764721438377598.jpeg/orig
Create:
Image #6311173
URL: https://avatars.mds.yandex.net/get-mpic/5273154/img_id3838851762569984438.jpeg/orig
Create:
Image #6311174
URL: https://avatars.mds.yandex.net/get-mpic/1361544/img_id9025845140670669812.jpeg/orig
Create:
Image #6311175
URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id3178934152663987219.png/orig
Create:
Image #6311176
URL: https://avatars.mds.yandex.net/get-mpic/4519143/img_id8696006592469605050.png/orig
Create:
Image #6311177
URL: https://avatars.mds.yandex.net/get-mpic/4291905/img_id2746019229052421279.jpeg/orig
Create:
Image #6311178
URL: https://avatars.mds.yandex.net/get-mpic/1866164/img_id7700570835692877540.jpeg/orig
Create:
Image #6311179
URL: https://avatars.mds.yandex.net/get-mpic/3907093/img_id6739548510624794999.jpeg/orig
Create:
Image #6311180
URL: https://avatars.mds.yandex.net/get-mpic/5235688/img_id2295186215970432015.jpeg/orig
Create:
Image #6311181
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id6421872343204682319.png/orig
Create:
Preview image #6311182
URL: https://avatars.mds.yandex.net/get-mpic/4343038/img_id9188386564745035448.jpeg/orig
Donny Darko 30 April 2023 08:09:37
Name: Gas Vaillant ecoTEC plus VUW INT IV 246/5-5; Catalog: Heating boilers