Change history for item: Gas Vaillant ecoTEC plus VUW INT IV 246/5-5

  1. Donny Darko 07 July 2023 16:35:40
    1. Create: Description #3349351
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3349352
      Value: Gas, condensing
    3. Create: Burner #3349353
      Value: Gas
    4. Create: Number of circuits #3349354
      Value: Double-circuit
    5. Create: Thermal power #3349355
      Value: 3.80 - 20 kW
    6. Create: Thermal load #3349356
      Value: 4 - 20.40 kW
    7. Create: The combustion chamber #3349357
      Value: Closed
    8. Create: Efficiency #3349358
      Value: 109 %
    9. Create: Control #3349359
      Value: Electronic
    10. Create: Installation #3349360
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3349361
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3349362
      Value: Stainless steel
    13. Create: Mains voltage #3349363
      Value: Single-phase
    14. Create: Peculiarities #3349364
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3349365
      Value: 10 l
    16. Create: Equipment #3349366
      Value: Display
    17. Create: Fuel #3349367
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3349368
      Value: 2.6 cu. m/hour
    19. Create: LPG consumption #3349369
      Value: 1.9 kg/hour
    20. Create: Nominal pressure of natural gas #3349370
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3349371
      Value: 30 mbar
    22. Create: Heat carrier temperature #3349372
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3349373
      Value: 35 - 65 °С
    24. Create: Hot water capacity at t 30°C #3349374
      Value: 11.5 l/min
    25. Create: Max. water pressure in the DHW circuit #3349375
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3349376
      Value: 3 bar
    27. Create: Gas connection #3349377
      Value: 1/2"
    28. Create: Heating circuit connection #3349378
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3349379
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3349380
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3349381
      Value: Yes
    32. Create: Dimensions WxHxD #3349382
      Value: 440x720x338 mm
    33. Create: Weight #3349383
      Value: 35 kg
    34. Create: Additional Information #3349384
      Value: Crimp adapter for gas connection 1/2" -> 3/4" included
    35. Create: Image #6311170
      URL: https://avatars.mds.yandex.net/get-mpic/4343038/img_id9188386564745035448.jpeg/orig
    36. Create: Image #6311171
      URL: https://avatars.mds.yandex.net/get-mpic/7979270/img_id1825108660694792074.jpeg/orig
    37. Create: Image #6311172
      URL: https://avatars.mds.yandex.net/get-mpic/2017118/img_id1201764721438377598.jpeg/orig
    38. Create: Image #6311173
      URL: https://avatars.mds.yandex.net/get-mpic/5273154/img_id3838851762569984438.jpeg/orig
    39. Create: Image #6311174
      URL: https://avatars.mds.yandex.net/get-mpic/1361544/img_id9025845140670669812.jpeg/orig
    40. Create: Image #6311175
      URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id3178934152663987219.png/orig
    41. Create: Image #6311176
      URL: https://avatars.mds.yandex.net/get-mpic/4519143/img_id8696006592469605050.png/orig
    42. Create: Image #6311177
      URL: https://avatars.mds.yandex.net/get-mpic/4291905/img_id2746019229052421279.jpeg/orig
    43. Create: Image #6311178
      URL: https://avatars.mds.yandex.net/get-mpic/1866164/img_id7700570835692877540.jpeg/orig
    44. Create: Image #6311179
      URL: https://avatars.mds.yandex.net/get-mpic/3907093/img_id6739548510624794999.jpeg/orig
    45. Create: Image #6311180
      URL: https://avatars.mds.yandex.net/get-mpic/5235688/img_id2295186215970432015.jpeg/orig
    46. Create: Image #6311181
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id6421872343204682319.png/orig
    47. Create: Preview image #6311182
      URL: https://avatars.mds.yandex.net/get-mpic/4343038/img_id9188386564745035448.jpeg/orig
  2. Donny Darko 30 April 2023 08:09:37
    Name: Gas Vaillant ecoTEC plus VUW INT IV 246/5-5; Catalog: Heating boilers