Donny Darko 07 July 2023 16:35:21
Create:
Description #3349204
Value: Type of heating boiler: gas, max. thermal power: 14 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3349205
Value: Gas, condensing
Create:
Burner #3349206
Value: Gas
Create:
Number of circuits #3349207
Value: Single-loop
Create:
Thermal power #3349208
Value: 3 - 14 kW
Create:
Thermal load #3349209
Value: 3.20 - 14.30 kW
Create:
The combustion chamber #3349210
Value: Closed
Create:
Heated area #3349211
Value: 140 sq.m
Create:
Efficiency #3349212
Value: 108 %
Create:
Control #3349213
Value: Electronic
Create:
Installation #3349214
Value: Wall-mounted
Create:
Primary heat exchanger material #3349215
Value: Stainless steel
Create:
Secondary heat exchanger material #3349216
Value: Stainless steel
Create:
Mains voltage #3349217
Value: Single-phase
Create:
Peculiarities #3349218
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3349219
Value: 10 l
Create:
Equipment #3349220
Value: Built-in exhaust fan, display
Create:
Fuel #3349221
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3349222
Value: 1.3 kg/hour
Create:
Natural gas consumption #3349223
Value: 1.7 cu. m/hour
Create:
LPG consumption #3349224
Value: 1.3 kg/hour
Create:
Nominal pressure of natural gas #3349225
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3349226
Value: 30 mbar
Create:
Heat carrier temperature #3349227
Value: 30 - 85 °С
Create:
Max. water pressure in the heating circuit #3349228
Value: 3 bar
Create:
Gas connection #3349229
Value: 3/4"
Create:
Heating circuit connection #3349230
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3349231
Value: 1/2"
Create:
Coaxial chimney diameter #3349232
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3349233
Value: Yes
Create:
Dimensions WxHxD #3349234
Value: 440x720x338 mm
Create:
Weight #3349235
Value: 33 kg
Create:
Image #6311118
URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id1405778824951215002.jpeg/orig
Create:
Image #6311119
URL: https://avatars.mds.yandex.net/get-mpic/4449143/img_id9010595676065853932.png/orig
Create:
Image #6311120
URL: https://avatars.mds.yandex.net/get-mpic/5221948/img_id1167362739418470702.jpeg/orig
Create:
Image #6311121
URL: https://avatars.mds.yandex.net/get-mpic/4370207/img_id4138206006881937305.jpeg/orig
Create:
Image #6311122
URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id5030836582594671660.jpeg/orig
Create:
Image #6311123
URL: https://avatars.mds.yandex.net/get-mpic/4114383/img_id4772344821235594217.jpeg/orig
Create:
Image #6311124
URL: https://avatars.mds.yandex.net/get-mpic/4415357/img_id9107358622564487974.jpeg/orig
Create:
Image #6311125
URL: https://avatars.mds.yandex.net/get-mpic/5236698/img_id4216650975715860609.png/orig
Create:
Image #6311126
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id2342704147400686900.png/orig
Create:
Image #6311127
URL: https://avatars.mds.yandex.net/get-mpic/5236584/img_id5522325572145036665.jpeg/orig
Create:
Image #6311128
URL: https://avatars.mds.yandex.net/get-mpic/4291905/img_id2746019229052421279.jpeg/orig
Create:
Image #6311129
URL: https://avatars.mds.yandex.net/get-mpic/1866164/img_id7700570835692877540.jpeg/orig
Create:
Image #6311130
URL: https://avatars.mds.yandex.net/get-mpic/3907093/img_id6739548510624794999.jpeg/orig
Create:
Image #6311131
URL: https://avatars.mds.yandex.net/get-mpic/5235688/img_id2295186215970432015.jpeg/orig
Create:
Image #6311132
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id6421872343204682319.png/orig
Create:
Preview image #6311133
URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id1405778824951215002.jpeg/orig
Donny Darko 30 April 2023 08:09:35
Name: Gas Vaillant ecoTEC plus VU INT IV 166/5-5; Catalog: Heating boilers