Change history for item: Gas Junkers Ceraclass Smart ZWA 24-2 A 24 kW double-circuit

  1. Donny Darko 07 July 2023 16:32:53
    1. Create: Description #3348252
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3348253
      Value: Gas, convection
    3. Create: Burner #3348254
      Value: Gas
    4. Create: Number of circuits #3348255
      Value: Double-circuit
    5. Create: Thermal power #3348256
      Value: 7.80 - 24 kW
    6. Create: Thermal load #3348257
      Value: 8.90 - 26.70 kW
    7. Create: The combustion chamber #3348258
      Value: Open
    8. Create: Efficiency #3348259
      Value: 89.8 %
    9. Create: Control #3348260
      Value: Electronic
    10. Create: Installation #3348261
      Value: Wall-mounted
    11. Create: Mains voltage #3348262
      Value: Single-phase
    12. Create: Peculiarities #3348263
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3348264
      Value: 8 l
    14. Create: Equipment #3348265
      Value: Display
    15. Create: Fuel #3348266
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3348267
      Value: 2.75 cu. m/hour
    17. Create: LPG consumption #3348268
      Value: 1.88 kg/h
    18. Create: Nominal pressure of natural gas #3348269
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3348270
      Value: 37 mbar
    20. Create: Max. coolant temperature #3348271
      Value: 82 °С
    21. Create: Temperature in the DHW circuit #3348272
      Value: 40 - 60 °С
    22. Create: Hot water capacity at t 20°C #3348273
      Value: 17.1 l/min
    23. Create: Hot water capacity at t 30°C #3348274
      Value: 11.4 l/min
    24. Create: Hot water capacity at t 50°C #3348275
      Value: 6.84 l/min
    25. Create: Max. water pressure in the DHW circuit #3348276
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3348277
      Value: 3 bar
    27. Create: Dimensions WxHxD #3348278
      Value: 400x750x355mm
    28. Create: Weight #3348279
      Value: 33 kg
    29. Create: Image #6310976
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id951106769409344649/orig
    30. Create: Preview image #6310977
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id951106769409344649/orig
  2. Donny Darko 30 April 2023 08:09:25
    Name: Gas Junkers Ceraclass Smart ZWA 24-2 A 24 kW double-circuit; Catalog: Heating boilers