Change history for item: Gas Junkers Ceraclass Excellence ZWC 28-3 MFK 28.1 kW double-circuit

  1. Donny Darko 07 July 2023 16:30:27
    1. Create: Description #3347465
      Value: Type of heating boiler: gas, max. heating power: 28.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3347466
      Value: Gas, convection
    3. Create: Burner #3347467
      Value: Gas
    4. Create: Number of circuits #3347468
      Value: Double-circuit
    5. Create: Thermal power #3347469
      Value: 8.60 - 28.10 kW
    6. Create: Thermal load #3347470
      Value: 9.80 - 31.30 kW
    7. Create: The combustion chamber #3347471
      Value: Open
    8. Create: Control #3347472
      Value: Electronic
    9. Create: Installation #3347473
      Value: Wall-mounted
    10. Create: Mains voltage #3347474
      Value: Single-phase
    11. Create: Peculiarities #3347475
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3347476
      Value: 8 l
    13. Create: Equipment #3347477
      Value: Display
    14. Create: Fuel #3347478
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3347479
      Value: 3.2 cu. m/hour
    16. Create: LPG consumption #3347480
      Value: 2.3 kg/hour
    17. Create: Nominal pressure of natural gas #3347481
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3347482
      Value: 37 mbar
    19. Create: Max. coolant temperature #3347483
      Value: 88 °С
    20. Create: Temperature in the DHW circuit #3347484
      Value: 40 - 60 °С
    21. Create: Hot water capacity at t 20°C #3347485
      Value: 20.1 l/min
    22. Create: Hot water capacity at t 30°C #3347486
      Value: 13.4 l/min
    23. Create: Hot water capacity at t 50°C #3347487
      Value: 8.1 l/min
    24. Create: Max. water pressure in the DHW circuit #3347488
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3347489
      Value: 3 bar
    26. Create: Gas connection #3347490
      Value: 3/4"
    27. Create: Heating circuit connection #3347491
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3347492
      Value: 1/2"
    29. Create: Chimney diameter #3347493
      Value: 130 mm
    30. Create: Dimensions WxHxD #3347494
      Value: 440x850x370 mm
    31. Create: Weight #3347495
      Value: 38.8 kg
    32. Create: Image #6310906
      URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id8995163345041225264/orig
    33. Create: Preview image #6310907
      URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id8995163345041225264/orig
  2. Donny Darko 30 April 2023 08:09:15
    Name: Gas Junkers Ceraclass Excellence ZWC 28-3 MFK 28.1 kW double-circuit; Catalog: Heating boilers