      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3347435
      Value: Gas, convection
    3. Create: Burner #3347436
      Value: Gas
    4. Create: Number of circuits #3347437
      Value: Double-circuit
    5. Create: Thermal power #3347438
      Value: 7.30 - 24 kW
    6. Create: Thermal load #3347439
      Value: 8.40 - 26.70 kW
    7. Create: The combustion chamber #3347440
      Value: Open
    8. Create: Control #3347441
      Value: Electronic
    9. Create: Installation #3347442
      Value: Wall-mounted
    10. Create: Mains voltage #3347443
      Value: Single-phase
    11. Create: Peculiarities #3347444
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3347445
      Value: 8 l
    13. Create: Equipment #3347446
      Value: Display
    14. Create: Fuel #3347447
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3347448
      Value: 2.8 cu. m/hour
    16. Create: LPG consumption #3347449
      Value: 2 kg/hour
    17. Create: Nominal pressure of natural gas #3347450
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3347451
      Value: 37 mbar
    19. Create: Max. coolant temperature #3347452
      Value: 88 °С
    20. Create: Temperature in the DHW circuit #3347453
      Value: 40 - 60 °С
    21. Create: Hot water capacity at t 20°C #3347454
      Value: 17.2 l/min
    22. Create: Hot water capacity at t 30°C #3347455
      Value: 11.5 l/min
    23. Create: Hot water capacity at t 50°C #3347456
      Value: 6.9 l/min
    24. Create: Max. water pressure in the DHW circuit #3347457
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3347458
      Value: 3 bar
    26. Create: Gas connection #3347459
      Value: 3/4"
    27. Create: Heating circuit connection #3347460
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3347461
      Value: 1/2"
    29. Create: Chimney diameter #3347462
      Value: 130 mm
    30. Create: Dimensions WxHxD #3347463
      Value: 400x850x370 mm
    31. Create: Weight #3347464
      Value: 36.1 kg
    32. Create: Image #6310904
      URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id8995163345041225264/orig
    33. Create: Preview image #6310905
      URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id8995163345041225264/orig
  2. Donny Darko 30 April 2023 08:09:14
    Name: Gas Junkers Ceraclass Excellence ZWC 24-3 MFK 24 kW double-circuit; Catalog: Heating boilers