Change history for item: Liquid fuel De Dietrich GTU 1205 S/ L 250 33 kW double-circuit

  1. Donny Darko 07 July 2023 16:18:13
    1. Create: Description #3344927
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3344928
      Value: Liquid fuel, classic
    3. Create: Burner #3344929
      Value: Liquid fuel
    4. Create: Number of circuits #3344930
      Value: Double-circuit
    5. Create: Thermal power #3344931
      Value: 27 - 33 kW
    6. Create: The combustion chamber #3344932
      Value: Open
    7. Create: Efficiency #3344933
      Value: 92.2 %
    8. Create: Control #3344934
      Value: Without control panel
    9. Create: Installation #3344935
      Value: Floor
    10. Create: Primary heat exchanger material #3344936
      Value: Cast iron
    11. Create: Mains voltage #3344937
      Value: Single-phase
    12. Create: The volume of the built-in boiler #3344938
      Value: 250 l
    13. Create: Equipment #3344939
      Value: Built-in boiler, display
    14. Create: Fuel #3344940
      Value: Diesel fuel
    15. Create: Heat carrier temperature #3344941
      Value: 30 - 90 °С
    16. Create: Max. temperature in the DHW circuit #3344942
      Value: 70 °С
    17. Create: Hot water capacity at t 30°C #3344943
      Value: 30 l/min
    18. Create: Max. water pressure in the DHW circuit #3344944
      Value: 10 bar
    19. Create: Max. water pressure in the heating circuit #3344945
      Value: 4 bar
    20. Create: Heating circuit connection #3344946
      Value: 1"
    21. Create: Branch pipe for connecting the DHW circuit #3344947
      Value: 1"
    22. Create: Chimney diameter #3344948
      Value: 125 mm
    23. Create: Dimensions WxHxD #3344949
      Value: 570x1453x1114 mm
    24. Create: Weight #3344950
      Value: 358 kg
    25. Create: Additional Information #3344951
      Value: Optional control panels: panel B Basic, panel D Diematic 3; oil heated burner
    26. Create: Image #6310521
      URL: https://avatars.mds.yandex.net/get-mpic/1525215/img_id923465245379550567/orig
    27. Create: Preview image #6310522
      URL: https://avatars.mds.yandex.net/get-mpic/1525215/img_id923465245379550567/orig
  2. Donny Darko 30 April 2023 08:08:28
    Name: Liquid fuel De Dietrich GTU 1205 S/ L 250 33 kW double-circuit; Catalog: Heating boilers