Change history for item: Gas ACV Kompakt HR eco 24/28 double-circuit

  1. Donny Darko 07 July 2023 16:11:40
    1. Create: Description #3342989
      Value: Type of heating boiler: gas, max. heating power: 26.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3342990
      Value: Gas, condensing
    3. Create: Burner #3342991
      Value: Gas
    4. Create: Number of circuits #3342992
      Value: Double-circuit
    5. Create: Thermal power #3342993
      Value: 7.90 - 26.30 kW
    6. Create: The combustion chamber #3342994
      Value: Closed
    7. Create: Control #3342995
      Value: Electronic
    8. Create: Installation #3342996
      Value: Wall-mounted
    9. Create: Mains voltage #3342997
      Value: Single-phase
    10. Create: Peculiarities #3342998
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge
    11. Create: Expansion tank volume #3342999
      Value: 8 l
    12. Create: Equipment #3343000
      Value: Display
    13. Create: Fuel #3343001
      Value: Natural gas, liquefied gas
    14. Create: Natural gas consumption #3343002
      Value: 2.9 cu. m/hour
    15. Create: Nominal pressure of natural gas #3343003
      Value: 20 mbar
    16. Create: Max. coolant temperature #3343004
      Value: 90 °С
    17. Create: Max. temperature in the DHW circuit #3343005
      Value: 65 °С
    18. Create: Hot water capacity at t 40°C #3343006
      Value: 12.5 l/min
    19. Create: Max. water pressure in the DHW circuit #3343007
      Value: 8.6 bar
    20. Create: Max. water pressure in the heating circuit #3343008
      Value: 3 bar
    21. Create: Gas connection #3343009
      Value: 1/2"
    22. Create: Heating circuit connection #3343010
      Value: 3/4"
    23. Create: Branch pipe for connecting the DHW circuit #3343011
      Value: 1/2"
    24. Create: Coaxial chimney diameter #3343012
      Value: 60/100 mm
    25. Create: Connection of a separate chimney diameter 80 mm #3343013
      Value: Yes
    26. Create: Dimensions WxHxD #3343014
      Value: 450x750x270 mm
    27. Create: Weight #3343015
      Value: 36 kg
    28. Create: Image #6310283
      URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id3223452025681747008.jpeg/orig
    29. Create: Image #6310284
      URL: https://avatars.mds.yandex.net/get-mpic/4012371/img_id8840789338376828944.jpeg/orig
    30. Create: Preview image #6310285
      URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id3223452025681747008.jpeg/orig
  2. Donny Darko 30 April 2023 08:08:02
    Name: Gas ACV Kompakt HR eco 24/28 double-circuit; Catalog: Heating boilers