Change history for item: Gas ACV HeatMaster 35 TC

  1. Donny Darko 07 July 2023 16:05:59
    1. Create: Description #3341431
      Value: Type of heating boiler: gas, max. thermal power: 34.10 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3341432
      Value: Gas, condensing
    3. Create: Burner #3341433
      Value: Gas
    4. Create: Number of circuits #3341434
      Value: Double-circuit
    5. Create: Thermal power #3341435
      Value: 9.90 - 34.10 kW
    6. Create: Thermal load #3341436
      Value: 10 - 34.90 kW
    7. Create: The combustion chamber #3341437
      Value: Closed
    8. Create: Efficiency #3341438
      Value: 106.6 %
    9. Create: Control #3341439
      Value: Electronic
    10. Create: Installation #3341440
      Value: Floor
    11. Create: Primary heat exchanger material #3341441
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3341442
      Value: Stainless steel
    13. Create: Mains voltage #3341443
      Value: Single-phase
    14. Create: Peculiarities #3341444
      Value: Air vent, built-in circulation pump, pressure gauge, safety valve, connector for external control
    15. Create: The volume of the built-in boiler #3341445
      Value: 94 l
    16. Create: Equipment #3341446
      Value: Built-in boiler, display
    17. Create: Fuel #3341447
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3341448
      Value: 4.3 cu. m/hour
    19. Create: LPG consumption #3341449
      Value: 2.4 kg/hour
    20. Create: Heat carrier temperature #3341450
      Value: 10 - 90 °С
    21. Create: Temperature in the DHW circuit #3341451
      Value: 10 - 80 °C
    22. Create: Hot water capacity at t 40°C #3341452
      Value: 17.8 l/min
    23. Create: Hot water capacity at t 45°C #3341453
      Value: 15.28 l/min
    24. Create: Max. water pressure in the DHW circuit #3341454
      Value: 75 bar
    25. Create: Max. water pressure in the heating circuit #3341455
      Value: 3 bar
    26. Create: Gas connection #3341456
      Value: 3/4"
    27. Create: Heating circuit connection #3341457
      Value: 1"
    28. Create: Branch pipe for connecting the DHW circuit #3341458
      Value: 1"
    29. Create: Coaxial chimney diameter #3341459
      Value: 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3341460
      Value: Yes
    31. Create: Dimensions WxHxD #3341461
      Value: 600x1720x670 mm
    32. Create: Weight #3341462
      Value: 174 kg
    33. Create: Image #6310112
      URL: https://avatars.mds.yandex.net/get-mpic/1681399/img_id2323212105763003245/orig
    34. Create: Image #6310113
      URL: https://avatars.mds.yandex.net/get-mpic/4322107/img_id228842672891606520.jpeg/orig
    35. Create: Preview image #6310114
      URL: https://avatars.mds.yandex.net/get-mpic/1681399/img_id2323212105763003245/orig
  2. Donny Darko 30 April 2023 08:07:42
    Name: Gas ACV HeatMaster 35 TC; Catalog: Heating boilers