Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:56:10
Create:
Description #3340116
Value: Type of heating boiler: gas, max. heating power: 24.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3340117
Value: Gas, convection
Create:
Burner #3340118
Value: Gas
Create:
Number of circuits #3340119
Value: Double-circuit
Create:
Thermal power #3340120
Value: 9 - 24.60 kW
Create:
Thermal load #3340121
Value: 10.50 - 27.10 kW
Create:
The combustion chamber #3340122
Value: Closed
Create:
Heated area #3340123
Value: 230 sq.m
Create:
Efficiency #3340124
Value: 97 %
Create:
Control #3340125
Value: Electronic
Create:
Installation #3340126
Value: Wall-mounted
Create:
Primary heat exchanger material #3340127
Value: Copper
Create:
Secondary heat exchanger material #3340128
Value: Stainless steel
Create:
Mains voltage #3340129
Value: Single-phase
Create:
Peculiarities #3340130
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Equipment #3340131
Value: Display
Create:
Fuel #3340132
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3340133
Value: 2.73 kg/h
Create:
Natural gas consumption #3340134
Value: 2.9 cu. m/hour
Create:
LPG consumption #3340135
Value: 2.1 kg/hour
Create:
Nominal pressure of natural gas #3340136
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3340137
Value: 30 mbar
Create:
Heat carrier temperature #3340138
Value: 35 - 83 °С
Create:
Temperature in the DHW circuit #3340139
Value: 35 - 65 °С
Create:
Hot water capacity at t 20°C #3340140
Value: 11.4 l/min
Create:
Hot water capacity at t 25°C #3340141
Value: 12.5 l/min
Create:
Hot water capacity at t 30°C #3340142
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3340143
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3340144
Value: 3 bar
Create:
Gas connection #3340145
Value: 3/4"
Create:
Heating circuit connection #3340146
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3340147
Value: 1/2"
Create:
Coaxial chimney diameter #3340148
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3340149
Value: Yes
Create:
Dimensions WxHxD #3340150
Value: 410x740x310 mm
Create:
Weight #3340151
Value: 33 kg
Create:
Image #6309485
URL: https://avatars.mds.yandex.net/get-mpic/4606255/img_id1781151197570836624.jpeg/orig
Create:
Image #6309486
URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id4311246209603103527.jpeg/orig
Create:
Image #6309487
URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id1508776356853617074.jpeg/orig
Create:
Image #6309488
URL: https://avatars.mds.yandex.net/get-mpic/1674591/img_id5985842249141180427.jpeg/orig
Create:
Image #6309489
URL: https://avatars.mds.yandex.net/get-mpic/1927422/img_id1853451381694484070.jpeg/orig
Create:
Image #6309490
URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id7878573552704634994.jpeg/orig
Create:
Image #6309491
URL: https://avatars.mds.yandex.net/get-mpic/4303439/img_id3224785600472195983.jpeg/orig
Create:
Image #6309492
URL: https://avatars.mds.yandex.net/get-mpic/5236584/img_id589031039729985768.jpeg/orig
Create:
Image #6309493
URL: https://avatars.mds.yandex.net/get-mpic/8139064/img_id5644117607852490083.jpeg/orig
Create:
Image #6309494
URL: https://avatars.mds.yandex.net/get-mpic/5346941/img_id2548471363284029048.jpeg/orig
Create:
Image #6309495
URL: https://avatars.mds.yandex.net/get-mpic/5284155/img_id7402451270234420028.png/orig
Create:
Preview image #6309496
URL: https://avatars.mds.yandex.net/get-mpic/4606255/img_id1781151197570836624.jpeg/orig
Donny Darko 30 April 2023 08:07:09
Name: Gas boiler Protherm Cheetah 23 MTV 2015; Catalog: Heating boilers