Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:55:30
Create:
Description #3339832
Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3339833
Value: Gas, convection
Create:
Burner #3339834
Value: Gas
Create:
Number of circuits #3339835
Value: Double-circuit
Create:
Thermal power #3339836
Value: 8.40 - 25 kW
Create:
Thermal load #3339837
Value: 9.40 - 27.10 kW
Create:
The combustion chamber #3339838
Value: Closed
Create:
Heated area #3339839
Value: 250 sq.m
Create:
Efficiency #3339840
Value: 92 %
Create:
Control #3339841
Value: Electronic
Create:
Installation #3339842
Value: Wall-mounted
Create:
Primary heat exchanger material #3339843
Value: Copper
Create:
Secondary heat exchanger material #3339844
Value: Stainless steel
Create:
Mains voltage #3339845
Value: Single-phase
Create:
Peculiarities #3339846
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3339847
Value: 10 l
Create:
Equipment #3339848
Value: Display
Create:
Fuel #3339849
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3339850
Value: 2.8 cu. m/hour
Create:
LPG consumption #3339851
Value: 2.06 kg/h
Create:
Nominal pressure of natural gas #3339852
Value: 13 - 25 mbar
Create:
Permissible LPG pressure #3339853
Value: 35 mbar
Create:
Heat carrier temperature #3339854
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3339855
Value: 35 - 65 °С
Create:
Hot water capacity at t 30°C #3339856
Value: 11.7 l/min
Create:
Max. water pressure in the DHW circuit #3339857
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3339858
Value: 3 bar
Create:
Gas connection #3339859
Value: 1/2"
Create:
Heating circuit connection #3339860
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3339861
Value: 3/4"
Create:
Coaxial chimney diameter #3339862
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3339863
Value: Yes
Create:
Dimensions WxHxD #3339864
Value: 440x800x338 mm
Create:
Weight #3339865
Value: 41 kg
Create:
Image #6309340
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id1302278569310217984.jpeg/orig
Create:
Image #6309341
URL: https://avatars.mds.yandex.net/get-mpic/1865723/img_id8250064109208725984.jpeg/orig
Create:
Image #6309342
URL: https://avatars.mds.yandex.net/get-mpic/1600461/img_id4978327031340243243.jpeg/orig
Create:
Image #6309343
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id6344002126153713705.jpeg/orig
Create:
Image #6309344
URL: https://avatars.mds.yandex.net/get-mpic/5236803/img_id1844664691553589799.jpeg/orig
Create:
Image #6309345
URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id2569119751608046072.jpeg/orig
Create:
Image #6309346
URL: https://avatars.mds.yandex.net/get-mpic/4606255/img_id3143740891305637331.jpeg/orig
Create:
Image #6309347
URL: https://avatars.mds.yandex.net/get-mpic/1681399/img_id8769673081586109314.jpeg/orig
Create:
Image #6309348
URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id602475584898132948.jpeg/orig
Create:
Image #6309349
URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id8966768002510557690.jpeg/orig
Create:
Image #6309350
URL: https://avatars.mds.yandex.net/get-mpic/7979606/img_id508267008025063291.jpeg/orig
Create:
Image #6309351
URL: https://avatars.mds.yandex.net/get-mpic/5266697/img_id6679558095947059939.jpeg/orig
Create:
Image #6309352
URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id731298301793334939.jpeg/orig
Create:
Preview image #6309353
URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id1302278569310217984.jpeg/orig
Donny Darko 30 April 2023 08:07:06
Name: Gas boiler Protherm Panther 25 KTV 2015; Catalog: Heating boilers