Change history for item: Gas boiler Protherm Lynx condensing 18/25 MKV

  1. Donny Darko 07 July 2023 15:55:02
    1. Create: Description #3339634
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3339635
      Value: Gas, condensing
    3. Create: Burner #3339636
      Value: Gas
    4. Create: Number of circuits #3339637
      Value: Double-circuit
    5. Create: Thermal power #3339638
      Value: 5 - 18 kW
    6. Create: Thermal load #3339639
      Value: 5.10 - 18.40 kW
    7. Create: The combustion chamber #3339640
      Value: Closed
    8. Create: Efficiency #3339641
      Value: 104 %
    9. Create: Control #3339642
      Value: Electronic
    10. Create: Installation #3339643
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3339644
      Value: Aluminum
    12. Create: Mains voltage #3339645
      Value: Single-phase
    13. Create: Peculiarities #3339646
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3339647
      Value: 8 l
    15. Create: Equipment #3339648
      Value: Display
    16. Create: Fuel #3339649
      Value: Natural gas
    17. Create: Natural gas consumption #3339650
      Value: 2.7 cu. m/hour
    18. Create: Nominal pressure of natural gas #3339651
      Value: 13 - 20 mbar
    19. Create: Heat carrier temperature #3339652
      Value: 10 - 80 °C
    20. Create: Temperature in the DHW circuit #3339653
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 30°C #3339654
      Value: 12.1 l/min
    22. Create: Max. water pressure in the DHW circuit #3339655
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3339656
      Value: 3 bar
    24. Create: Gas connection #3339657
      Value: 1/2"
    25. Create: Heating circuit connection #3339658
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3339659
      Value: 3/4"
    27. Create: Coaxial chimney diameter #3339660
      Value: 60/100 mm and 80/125 mm
    28. Create: Dimensions WxHxD #3339661
      Value: 390x700x280mm
    29. Create: Weight #3339662
      Value: 35 kg
    30. Create: Image #6309265
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7654955360292693980/orig
    31. Create: Image #6309266
      URL: https://avatars.mds.yandex.net/get-mpic/5418200/img_id84870618998948277.jpeg/orig
    32. Create: Image #6309267
      URL: https://avatars.mds.yandex.net/get-mpic/4880383/img_id328594566555538078.jpeg/orig
    33. Create: Image #6309268
      URL: https://avatars.mds.yandex.net/get-mpic/5286714/img_id4101786584580249427.png/orig
    34. Create: Image #6309269
      URL: https://avatars.mds.yandex.net/get-mpic/5288039/img_id7430611400386294876.png/orig
    35. Create: Image #6309270
      URL: https://avatars.mds.yandex.net/get-mpic/5173454/img_id4333490962298061449.png/orig
    36. Create: Image #6309271
      URL: https://avatars.mds.yandex.net/get-mpic/1886039/img_id4358465446433813368.jpeg/orig
    37. Create: Preview image #6309272
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7654955360292693980/orig
  2. Donny Darko 30 April 2023 08:07:04
    Name: Gas boiler Protherm Lynx condensing 18/25 MKV; Catalog: Heating boilers