      Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3339289
      Value: Gas, convection
    3. Create: Burner #3339290
      Value: Gas
    4. Create: Number of circuits #3339291
      Value: Double-circuit
    5. Create: Thermal power #3339292
      Value: 11.20 - 35 kW
    6. Create: Thermal load #3339293
      Value: 13 - 38.40 kW
    7. Create: The combustion chamber #3339294
      Value: Closed
    8. Create: Efficiency #3339295
      Value: 92.8 %
    9. Create: Control #3339296
      Value: Electronic
    10. Create: Installation #3339297
      Value: Wall-mounted
    11. Create: Mains voltage #3339298
      Value: Single-phase
    12. Create: Peculiarities #3339299
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3339300
      Value: 10 l
    14. Create: Equipment #3339301
      Value: Display, room thermostat
    15. Create: Fuel #3339302
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3339303
      Value: 4.1 cu. m/hour
    17. Create: LPG consumption #3339304
      Value: 1.46 kg/h
    18. Create: Nominal pressure of natural gas #3339305
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3339306
      Value: 30 mbar
    20. Create: Heat carrier temperature #3339307
      Value: 30 - 85 °С
    21. Create: Temperature in the DHW circuit #3339308
      Value: 38 - 60 °С
    22. Create: Hot water capacity at t 30°C #3339309
      Value: 16.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3339310
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3339311
      Value: 3 bar
    25. Create: Gas connection #3339312
      Value: 1/2"
    26. Create: Heating circuit connection #3339313
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3339314
      Value: 3/4"
    28. Create: Coaxial chimney diameter #3339315
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3339316
      Value: 450x798x365 mm
    30. Create: Weight #3339317
      Value: 39 kg
    31. Create: Image #6309188
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id4113939564023049911.jpeg/orig
    32. Create: Image #6309189
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id7538467433988811003.jpeg/orig
    33. Create: Preview image #6309190
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id4113939564023049911.jpeg/orig
  2. Donny Darko 30 April 2023 08:07:01
    Name: Gas boiler Protherm Panther 35 KTV 2010; Catalog: Heating boilers