Change history for item: Gas boiler Protherm Lynx 28 27 kW double-circuit

  1. Donny Darko 07 July 2023 15:53:43
    1. Create: Description #3339169
      Value: Type of heating boiler: gas, max. thermal power: 27 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3339170
      Value: Gas, convection
    3. Create: Burner #3339171
      Value: Gas
    4. Create: Number of circuits #3339172
      Value: Double-circuit
    5. Create: Thermal power #3339173
      Value: 11.30 - 27 kW
    6. Create: Thermal load #3339174
      Value: 13 - 29.10 kW
    7. Create: The combustion chamber #3339175
      Value: Closed
    8. Create: Heated area #3339176
      Value: 270 sq.m
    9. Create: Efficiency #3339177
      Value: 92.9 %
    10. Create: Control #3339178
      Value: Electronic
    11. Create: Installation #3339179
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3339180
      Value: Stainless steel
    13. Create: Mains voltage #3339181
      Value: Single-phase
    14. Create: Peculiarities #3339182
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    15. Create: Expansion tank volume #3339183
      Value: 7 l
    16. Create: Equipment #3339184
      Value: Display
    17. Create: Fuel #3339185
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3339186
      Value: 3.079 cu. m/hour
    19. Create: LPG consumption #3339187
      Value: 2.26 kg/hour
    20. Create: Nominal pressure of natural gas #3339188
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3339189
      Value: 30 mbar
    22. Create: Max. coolant temperature #3339190
      Value: 85 °С
    23. Create: Max. temperature in the DHW circuit #3339191
      Value: 64 °С
    24. Create: Hot water capacity at t 30°C #3339192
      Value: 12.7 l/min
    25. Create: Max. water pressure in the DHW circuit #3339193
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3339194
      Value: 3 bar
    27. Create: Gas connection #3339195
      Value: 3/4"
    28. Create: Heating circuit connection #3339196
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3339197
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3339198
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3339199
      Value: Yes
    32. Create: Dimensions WxHxD #3339200
      Value: 444x700x280 mm
    33. Create: Weight #3339201
      Value: 33 kg
    34. Create: Image #6309173
      URL: https://avatars.mds.yandex.net/get-mpic/1522540/img_id6000339186437480768/orig
    35. Create: Image #6309174
      URL: https://avatars.mds.yandex.net/get-mpic/6303765/img_id5256322909304796126.jpeg/orig
    36. Create: Image #6309175
      URL: https://avatars.mds.yandex.net/get-mpic/7979706/img_id5004106782782483000.jpeg/orig
    37. Create: Image #6309176
      URL: https://avatars.mds.yandex.net/get-mpic/7498982/img_id7671069256967561476.jpeg/orig
    38. Create: Image #6309177
      URL: https://avatars.mds.yandex.net/get-mpic/7516494/img_id8314368547733654461.jpeg/orig
    39. Create: Image #6309178
      URL: https://avatars.mds.yandex.net/get-mpic/5217715/img_id3635426168157127300.jpeg/orig
    40. Create: Image #6309179
      URL: https://avatars.mds.yandex.net/get-mpic/4334746/img_id5004953301150220145.jpeg/orig
    41. Create: Preview image #6309180
      URL: https://avatars.mds.yandex.net/get-mpic/1522540/img_id6000339186437480768/orig
  2. Donny Darko 30 April 2023 08:07:00
    Name: Gas boiler Protherm Lynx 28 27 kW double-circuit; Catalog: Heating boilers