    1. Create: Description #3339138
      Value: Type of heating boiler: gas, max. heating power: 23.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3339139
      Value: Gas, convection
    3. Create: Burner #3339140
      Value: Gas
    4. Create: Number of circuits #3339141
      Value: Double-circuit
    5. Create: Thermal power #3339142
      Value: 10 - 23.30 kW
    6. Create: Thermal load #3339143
      Value: 11.50 - 25.60 kW
    7. Create: The combustion chamber #3339144
      Value: Open
    8. Create: Efficiency #3339145
      Value: 91.1 %
    9. Create: Control #3339146
      Value: Electronic
    10. Create: Installation #3339147
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3339148
      Value: Stainless steel
    12. Create: Mains voltage #3339149
      Value: Single-phase
    13. Create: Peculiarities #3339150
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3339151
      Value: 7 l
    15. Create: Equipment #3339152
      Value: Display
    16. Create: Fuel #3339153
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3339154
      Value: 2.709 cu. m/hour
    18. Create: LPG consumption #3339155
      Value: 1.989 kg/h
    19. Create: Nominal pressure of natural gas #3339156
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3339157
      Value: 30 mbar
    21. Create: Max. coolant temperature #3339158
      Value: 85 °С
    22. Create: Max. temperature in the DHW circuit #3339159
      Value: 64 °С
    23. Create: Hot water capacity at t 30°C #3339160
      Value: 10.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3339161
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3339162
      Value: 3 bar
    26. Create: Gas connection #3339163
      Value: 3/4"
    27. Create: Heating circuit connection #3339164
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3339165
      Value: 1/2"
    29. Create: Chimney diameter #3339166
      Value: 130 mm
    30. Create: Dimensions WxHxD #3339167
      Value: 405x700x330 mm
    31. Create: Weight #3339168
      Value: 305 kg
    32. Create: Image #6309171
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3873399990661956764/orig
    33. Create: Preview image #6309172
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3873399990661956764/orig
  2. Donny Darko 30 April 2023 08:06:59
    Name: Gas boiler Protherm Lynx VA 24 23.3 kW double-circuit; Catalog: Heating boilers