Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:53:23
Create:
Description #3339072
Value: Type of heating boiler: gas, max. heating power: 22.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3339073
Value: Gas, convection
Create:
Burner #3339074
Value: Gas
Create:
Number of circuits #3339075
Value: Double-circuit
Create:
Thermal power #3339076
Value: 8.90 - 22.30 kW
Create:
Thermal load #3339077
Value: 10.80 - 24.50 kW
Create:
The combustion chamber #3339078
Value: Closed
Create:
Efficiency #3339079
Value: 90 %
Create:
Control #3339080
Value: Electronic
Create:
Installation #3339081
Value: Wall-mounted
Create:
Mains voltage #3339082
Value: Single-phase
Create:
Peculiarities #3339083
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3339084
Value: 5 l
Create:
Equipment #3339085
Value: Display
Create:
Fuel #3339086
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3339087
Value: 2.6 cu. m/hour
Create:
LPG consumption #3339088
Value: 1.66 kg/hour
Create:
Nominal pressure of natural gas #3339089
Value: 18 mbar
Create:
Permissible LPG pressure #3339090
Value: 30 mbar
Create:
Heat carrier temperature #3339091
Value: 40 - 80 °С
Create:
Temperature in the DHW circuit #3339092
Value: 40 - 60 °С
Create:
Hot water capacity at t 25°C #3339093
Value: 12.5 l/min
Create:
Hot water capacity at t 30°C #3339094
Value: 10.6 l/min
Create:
Hot water capacity at t 35°C #3339095
Value: 8.8 l/min
Create:
Max. water pressure in the DHW circuit #3339096
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3339097
Value: 3 bar
Create:
Gas connection #3339098
Value: 3/4"
Create:
Heating circuit connection #3339099
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3339100
Value: 1/2"
Create:
Coaxial chimney diameter #3339101
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3339102
Value: Yes
Create:
Dimensions WxHxD #3339103
Value: 410x740x320mm
Create:
Weight #3339104
Value: 33 kg
Create:
Image #6309152
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2024316306225342923/orig
Create:
Preview image #6309153
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2024316306225342923/orig
Donny Darko 30 April 2023 08:06:59
Name: Gas boiler Protherm Leopard 24 BTV 22.3 kW double-circuit; Catalog: Heating boilers