Change history for item: Gas boiler Protherm Leopard 24 BTV 22.3 kW double-circuit

  1. Donny Darko 07 July 2023 15:53:23
    1. Create: Description #3339072
      Value: Type of heating boiler: gas, max. heating power: 22.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3339073
      Value: Gas, convection
    3. Create: Burner #3339074
      Value: Gas
    4. Create: Number of circuits #3339075
      Value: Double-circuit
    5. Create: Thermal power #3339076
      Value: 8.90 - 22.30 kW
    6. Create: Thermal load #3339077
      Value: 10.80 - 24.50 kW
    7. Create: The combustion chamber #3339078
      Value: Closed
    8. Create: Efficiency #3339079
      Value: 90 %
    9. Create: Control #3339080
      Value: Electronic
    10. Create: Installation #3339081
      Value: Wall-mounted
    11. Create: Mains voltage #3339082
      Value: Single-phase
    12. Create: Peculiarities #3339083
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3339084
      Value: 5 l
    14. Create: Equipment #3339085
      Value: Display
    15. Create: Fuel #3339086
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3339087
      Value: 2.6 cu. m/hour
    17. Create: LPG consumption #3339088
      Value: 1.66 kg/hour
    18. Create: Nominal pressure of natural gas #3339089
      Value: 18 mbar
    19. Create: Permissible LPG pressure #3339090
      Value: 30 mbar
    20. Create: Heat carrier temperature #3339091
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3339092
      Value: 40 - 60 °С
    22. Create: Hot water capacity at t 25°C #3339093
      Value: 12.5 l/min
    23. Create: Hot water capacity at t 30°C #3339094
      Value: 10.6 l/min
    24. Create: Hot water capacity at t 35°C #3339095
      Value: 8.8 l/min
    25. Create: Max. water pressure in the DHW circuit #3339096
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3339097
      Value: 3 bar
    27. Create: Gas connection #3339098
      Value: 3/4"
    28. Create: Heating circuit connection #3339099
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3339100
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3339101
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3339102
      Value: Yes
    32. Create: Dimensions WxHxD #3339103
      Value: 410x740x320mm
    33. Create: Weight #3339104
      Value: 33 kg
    34. Create: Image #6309152
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2024316306225342923/orig
    35. Create: Preview image #6309153
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2024316306225342923/orig
  2. Donny Darko 30 April 2023 08:06:59
    Name: Gas boiler Protherm Leopard 24 BTV 22.3 kW double-circuit; Catalog: Heating boilers