Change history for item: Gas boiler Protherm Cheetah 23 MTV 2010

  1. Donny Darko 07 July 2023 15:52:47
    1. Create: Description #3338850
      Value: Type of heating boiler: gas, max. heating power: 23.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3338851
      Value: Gas, convection
    3. Create: Burner #3338852
      Value: Gas
    4. Create: Number of circuits #3338853
      Value: Double-circuit
    5. Create: Thermal power #3338854
      Value: 8.50 - 23.30 kW
    6. Create: Thermal load #3338855
      Value: 10.70 - 25 kW
    7. Create: The combustion chamber #3338856
      Value: Closed
    8. Create: Efficiency #3338857
      Value: 93.2 %
    9. Create: Control #3338858
      Value: Electronic
    10. Create: Installation #3338859
      Value: Wall-mounted
    11. Create: Mains voltage #3338860
      Value: Single-phase
    12. Create: Peculiarities #3338861
      Value: Built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3338862
      Value: 5 l
    14. Create: Equipment #3338863
      Value: Display
    15. Create: Fuel #3338864
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3338865
      Value: 2.64 cu. m/hour
    17. Create: LPG consumption #3338866
      Value: 1.84 kg/hour
    18. Create: Nominal pressure of natural gas #3338867
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3338868
      Value: 37 mbar
    20. Create: Heat carrier temperature #3338869
      Value: 38 - 85 °С
    21. Create: Temperature in the DHW circuit #3338870
      Value: 38 - 60 °С
    22. Create: Hot water capacity at t 30°C #3338871
      Value: 11.1 l/min
    23. Create: Max. water pressure in the DHW circuit #3338872
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3338873
      Value: 3 bar
    25. Create: Gas connection #3338874
      Value: 1/2"
    26. Create: Heating circuit connection #3338875
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3338876
      Value: 3/4"
    28. Create: Coaxial chimney diameter #3338877
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3338878
      Value: Yes
    30. Create: Dimensions WxHxD #3338879
      Value: 410x742x311 mm
    31. Create: Weight #3338880
      Value: 34 kg
    32. Create: Image #6309136
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7568826858980637408/orig
    33. Create: Preview image #6309137
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7568826858980637408/orig
  2. Donny Darko 30 April 2023 08:06:57
    Name: Gas boiler Protherm Cheetah 23 MTV 2010; Catalog: Heating boilers