Change history for item: Gas boiler Protherm Tiger 12 KTZ

  1. Donny Darko 07 July 2023 15:52:29
    1. Create: Description #3338755
      Value: Type of heating boiler: gas, max. heating power: 11.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3338756
      Value: Gas, convection
    3. Create: Burner #3338757
      Value: Gas
    4. Create: Number of circuits #3338758
      Value: Double-circuit
    5. Create: Thermal power #3338759
      Value: 3.50 - 11.20 kW
    6. Create: Thermal load #3338760
      Value: 4.20 - 12.30 kW
    7. Create: The combustion chamber #3338761
      Value: Closed
    8. Create: Efficiency #3338762
      Value: 91 %
    9. Create: Control #3338763
      Value: Electronic
    10. Create: Installation #3338764
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3338765
      Value: Copper
    12. Create: Mains voltage #3338766
      Value: Single-phase
    13. Create: Peculiarities #3338767
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: The volume of the built-in boiler #3338768
      Value: 4.5 l
    15. Create: Expansion tank volume #3338769
      Value: 8 l
    16. Create: Equipment #3338770
      Value: Built-in boiler, display
    17. Create: Fuel #3338771
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3338772
      Value: 1.3 cu. m/hour
    19. Create: LPG consumption #3338773
      Value: 0.93 kg/h
    20. Create: Nominal pressure of natural gas #3338774
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3338775
      Value: 30 mbar
    22. Create: Heat carrier temperature #3338776
      Value: 45 - 85 °С
    23. Create: Temperature in the DHW circuit #3338777
      Value: 38 - 70 °С
    24. Create: Hot water capacity at t 30°C #3338778
      Value: 8 l/min
    25. Create: Max. water pressure in the DHW circuit #3338779
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3338780
      Value: 3 bar
    27. Create: Gas connection #3338781
      Value: 1/2"
    28. Create: Heating circuit connection #3338782
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3338783
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3338784
      Value: 60/100 mm
    31. Create: Dimensions WxHxD #3338785
      Value: 410x900x570 mm
    32. Create: Weight #3338786
      Value: 70 kg
    33. Create: Image #6309130
      URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id1566727930339805147/orig
    34. Create: Preview image #6309131
      URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id1566727930339805147/orig
  2. Donny Darko 30 April 2023 08:06:56
    Name: Gas boiler Protherm Tiger 12 KTZ; Catalog: Heating boilers