Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:49:10
Create:
Description #3337707
Value: Type of heating boiler: gas, max. thermal power: 17 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
Create:
Type of heating boiler #3337708
Value: Gas, convection
Create:
Burner #3337709
Value: Gas
Create:
Number of circuits #3337710
Value: Double-circuit
Create:
Thermal power #3337711
Value: 12.10 - 17 kW
Create:
Thermal load #3337712
Value: 13 - 18.50 kW
Create:
The combustion chamber #3337713
Value: Open
Create:
Heated area #3337714
Value: 170 sq.m
Create:
Efficiency #3337715
Value: 90 %
Create:
Control #3337716
Value: Electronic
Create:
Installation #3337717
Value: Floor
Create:
Primary heat exchanger material #3337718
Value: Cast iron
Create:
Mains voltage #3337719
Value: Single-phase
Create:
Peculiarities #3337720
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
Create:
The volume of the built-in boiler #3337721
Value: 90 l
Create:
Expansion tank volume #3337722
Value: 10 l
Create:
Equipment #3337723
Value: Built-in boiler, display
Create:
Fuel #3337724
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3337725
Value: 2 cu. m/hour
Create:
LPG consumption #3337726
Value: 1.6 kg/hour
Create:
Nominal pressure of natural gas #3337727
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3337728
Value: 30 mbar
Create:
Heat carrier temperature #3337729
Value: 45 - 85 °С
Create:
Temperature in the DHW circuit #3337730
Value: 40 - 70 °C
Create:
Hot water capacity at t 30°C #3337731
Value: 16.5 l/min
Create:
Max. water pressure in the DHW circuit #3337732
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3337733
Value: 3 bar
Create:
Gas connection #3337734
Value: 3/4"
Create:
Heating circuit connection #3337735
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3337736
Value: 3/4"
Create:
Chimney diameter #3337737
Value: 130 mm
Create:
Dimensions WxHxD #3337738
Value: 505x1385x730 mm
Create:
Weight #3337739
Value: 140 kg
Create:
Additional Information #3337740
Value: 2-way heat exchanger; 3 sections
Create:
Image #6308700
URL: https://avatars.mds.yandex.net/get-mpic/4314340/img_id8651991519182155248.jpeg/orig
Create:
Image #6308701
URL: https://avatars.mds.yandex.net/get-mpic/5175047/img_id4055240320184529551.png/orig
Create:
Image #6308702
URL: https://avatars.mds.yandex.net/get-mpic/5241173/img_id4830819113122597056.jpeg/orig
Create:
Image #6308703
URL: https://avatars.mds.yandex.net/get-mpic/1599966/img_id3466336924644731551.jpeg/orig
Create:
Image #6308704
URL: https://avatars.mds.yandex.net/get-mpic/4529750/img_id5876185750801789265.jpeg/orig
Create:
Image #6308705
URL: https://avatars.mds.yandex.net/get-mpic/2008488/img_id6624665058873628250.jpeg/orig
Create:
Image #6308706
URL: https://avatars.mds.yandex.net/get-mpic/4408567/img_id2329791064705326103.jpeg/orig
Create:
Image #6308707
URL: https://avatars.mds.yandex.net/get-mpic/5233990/img_id2498215896241195774.jpeg/orig
Create:
Image #6308708
URL: https://avatars.mds.yandex.net/get-mpic/5313421/img_id6636523776959968403.jpeg/orig
Create:
Image #6308709
URL: https://avatars.mds.yandex.net/get-mpic/5277894/img_id651365813821715266.jpeg/orig
Create:
Preview image #6308710
URL: https://avatars.mds.yandex.net/get-mpic/4314340/img_id8651991519182155248.jpeg/orig
Donny Darko 30 April 2023 08:06:43
Name: Gas boiler Protherm Bear 20 KLZ; Catalog: Heating boilers