Change history for item: Gas boiler Protherm Panther 30 KTV 2010

  1. Donny Darko 07 July 2023 15:48:33
    1. Create: Description #3337499
      Value: Type of heating boiler: gas, max. heating power: 29.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3337500
      Value: Gas, convection
    3. Create: Burner #3337501
      Value: Gas
    4. Create: Number of circuits #3337502
      Value: Double-circuit
    5. Create: Thermal power #3337503
      Value: 10.40 - 29.60 kW
    6. Create: Thermal load #3337504
      Value: 12.20 - 32.50 kW
    7. Create: The combustion chamber #3337505
      Value: Closed
    8. Create: Efficiency #3337506
      Value: 92.8 %
    9. Create: Control #3337507
      Value: Electronic
    10. Create: Installation #3337508
      Value: Wall-mounted
    11. Create: Mains voltage #3337509
      Value: Single-phase
    12. Create: Peculiarities #3337510
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, thermometer
    13. Create: Expansion tank volume #3337511
      Value: 8 l
    14. Create: Equipment #3337512
      Value: Display, room thermostat
    15. Create: Fuel #3337513
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3337514
      Value: 3.44 cu. m/hour
    17. Create: LPG consumption #3337515
      Value: 3.21 kg/h
    18. Create: Nominal pressure of natural gas #3337516
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3337517
      Value: 30 mbar
    20. Create: Heat carrier temperature #3337518
      Value: 30 - 85 °С
    21. Create: Temperature in the DHW circuit #3337519
      Value: 38 - 60 °С
    22. Create: Hot water capacity at t 30°C #3337520
      Value: 14 l/min
    23. Create: Max. water pressure in the DHW circuit #3337521
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3337522
      Value: 3 bar
    25. Create: Gas connection #3337523
      Value: 1/2"
    26. Create: Heating circuit connection #3337524
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3337525
      Value: 3/4"
    28. Create: Coaxial chimney diameter #3337526
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3337527
      Value: 450x798x365 mm
    30. Create: Weight #3337528
      Value: 39 kg
    31. Create: Image #6308635
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id6736889345450808686.jpeg/orig
    32. Create: Image #6308636
      URL: https://avatars.mds.yandex.net/get-mpic/4466970/img_id5279452176078558158.jpeg/orig
    33. Create: Preview image #6308637
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id6736889345450808686.jpeg/orig
  2. Donny Darko 30 April 2023 08:06:42
    Name: Gas boiler Protherm Panther 30 KTV 2010; Catalog: Heating boilers