Description #3333982
Value: Type of heating boiler: gas, max. heating power: 29.70 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
Create:
Type of heating boiler #3333983
Value: Gas, convection
Create:
Burner #3333984
Value: Gas
Create:
Number of circuits #3333985
Value: Double-circuit
Create:
Thermal power #3333986
Value: 14.90 - 29.70 kW
Create:
Thermal load #3333987
Value: 17 - 33 kW
Create:
The combustion chamber #3333988
Value: Open
Create:
Efficiency #3333989
Value: 90 %
Create:
Control #3333990
Value: Electronic
Create:
Installation #3333991
Value: Floor
Create:
Primary heat exchanger material #3333992
Value: Cast iron
Create:
Mains voltage #3333993
Value: Single-phase
Create:
Peculiarities #3333994
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3333995
Value: 50 l
Create:
Expansion tank volume #3333996
Value: 10 l
Create:
Equipment #3333997
Value: Built-in boiler, display
Create:
Fuel #3333998
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3333999
Value: 3.49 cu. m/hour
Create:
LPG consumption #3334000
Value: 2.56 kg/h
Create:
Nominal pressure of natural gas #3334001
Value: 20 mbar
Create:
Permissible LPG pressure #3334002
Value: 30 mbar
Create:
Heat carrier temperature #3334003
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3334004
Value: 5 - 65 °С
Create:
Hot water capacity at t 25°C #3334005
Value: 17 l/min
Create:
Hot water capacity at t 35°C #3334006
Value: 12.1 l/min
Create:
Max. water pressure in the DHW circuit #3334007
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3334008
Value: 3 bar
Create:
Gas connection #3334009
Value: 1/2"
Create:
Heating circuit connection #3334010
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3334011
Value: 1/2"
Create:
Chimney diameter #3334012
Value: 140 mm
Create:
Dimensions WxHxD #3334013
Value: 650x850x600mm
Create:
Weight #3334014
Value: 192 kg
Create:
Additional Information #3334015
Value: Productivity of hot water for the first 30 minutes at Δt
Create:
Image #6307633
URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7220519732968821965.jpeg/orig
Create:
Image #6307634
URL: https://avatars.mds.yandex.net/get-mpic/4032471/img_id984515604568951475.jpeg/orig
Create:
Image #6307635
URL: https://avatars.mds.yandex.net/get-mpic/4525599/img_id3951410294885709908.jpeg/orig
Create:
Image #6307636
URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id4093416740087086866.jpeg/orig
Create:
Image #6307637
URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id831758373269683425.jpeg/orig
Create:
Image #6307638
URL: https://avatars.mds.yandex.net/get-mpic/5209489/img_id741175811304053902.jpeg/orig
Create:
Image #6307639
URL: https://avatars.mds.yandex.net/get-mpic/5279099/img_id4053711389157007261.jpeg/orig
Create:
Image #6307640
URL: https://avatars.mds.yandex.net/get-mpic/5326769/img_id3311733134547514522.jpeg/orig
Create:
Preview image #6307641
URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7220519732968821965.jpeg/orig
Donny Darko 30 April 2023 08:05:28
Name: Convection gas boiler BAXI SLIM 2.300 i, 29.7 kW, double-circuit; Catalog: Heating boilers