Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:28:15
Create:
Description #3333914
Value: Type of heating boiler: gas, max. heating power: 29.70 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3333915
Value: Gas, convection
Create:
Burner #3333916
Value: Gas
Create:
Number of circuits #3333917
Value: Double-circuit
Create:
Thermal power #3333918
Value: 14.90 - 29.70 kW
Create:
Thermal load #3333919
Value: 17 - 33 kW
Create:
The combustion chamber #3333920
Value: Closed
Create:
Efficiency #3333921
Value: 90 %
Create:
Control #3333922
Value: Electronic
Create:
Installation #3333923
Value: Floor
Create:
Primary heat exchanger material #3333924
Value: Cast iron
Create:
Mains voltage #3333925
Value: Single-phase
Create:
Peculiarities #3333926
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3333927
Value: 60 l
Create:
Expansion tank volume #3333928
Value: 10 l
Create:
Equipment #3333929
Value: Built-in boiler, display
Create:
Fuel #3333930
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3333931
Value: 3.49 cu. m/hour
Create:
LPG consumption #3333932
Value: 2.56 kg/h
Create:
Nominal pressure of natural gas #3333933
Value: 20 mbar
Create:
Permissible LPG pressure #3333934
Value: 30 mbar
Create:
Heat carrier temperature #3333935
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3333936
Value: 5 - 65 °С
Create:
Hot water capacity at t 25°C #3333937
Value: 17 l/min
Create:
Hot water capacity at t 35°C #3333938
Value: 12.2 l/min
Create:
Max. water pressure in the DHW circuit #3333939
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3333940
Value: 3 bar
Create:
Gas connection #3333941
Value: 1/2"
Create:
Heating circuit connection #3333942
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3333943
Value: 1/2"
Create:
Coaxial chimney diameter #3333944
Value: 60/100 mm
Create:
Dimensions WxHxD #3333945
Value: 650x850x600mm
Create:
Weight #3333946
Value: 192 kg
Create:
Additional Information #3333947
Value: Productivity of hot water for the first 30 minutes at Δt
Create:
Image #6307616
URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id2454436401525618929.jpeg/orig
Create:
Image #6307617
URL: https://avatars.mds.yandex.net/get-mpic/5210428/img_id134516915755634747.jpeg/orig
Create:
Image #6307618
URL: https://avatars.mds.yandex.net/get-mpic/5346941/img_id7078818268010201369.jpeg/orig
Create:
Image #6307619
URL: https://avatars.mds.yandex.net/get-mpic/1884605/img_id4062330813688103854.jpeg/orig
Create:
Image #6307620
URL: https://avatars.mds.yandex.net/get-mpic/5279099/img_id4053711389157007261.jpeg/orig
Create:
Image #6307621
URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id8353054783725591298.jpeg/orig
Create:
Image #6307622
URL: https://avatars.mds.yandex.net/get-mpic/5266697/img_id700991132627665562.jpeg/orig
Create:
Image #6307623
URL: https://avatars.mds.yandex.net/get-mpic/5235242/img_id1644635802618868540.jpeg/orig
Create:
Preview image #6307624
URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id2454436401525618929.jpeg/orig
Donny Darko 30 April 2023 08:05:28
Name: Convection gas boiler BAXI SLIM 2.300 Fi, 29.7 kW, double-circuit; Catalog: Heating boilers