Change history for item: Convection gas boiler BAXI MAIN 5 14 F, 14 kW, double-circuit

  1. Donny Darko 07 July 2023 15:27:59
    1. Create: Description #3333805
      Value: Type of heating boiler: gas, max. thermal power: 14 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3333806
      Value: Gas, convection
    3. Create: Burner #3333807
      Value: Gas
    4. Create: Number of circuits #3333808
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Max. thermal power #3333809
      Value: 14 kW
    6. Create: Thermal load #3333810
      Value: 7.10 - 15.06 kW
    7. Create: The combustion chamber #3333811
      Value: Closed
    8. Create: Efficiency #3333812
      Value: 90.7 %
    9. Create: Control #3333813
      Value: Electronic
    10. Create: Installation #3333814
      Value: Wall-mounted
    11. Create: Mains voltage #3333815
      Value: Single-phase
    12. Create: Peculiarities #3333816
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3333817
      Value: 6 l
    14. Create: Equipment #3333818
      Value: Display
    15. Create: Fuel #3333819
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3333820
      Value: 1.63 cu. m/hour
    17. Create: LPG consumption #3333821
      Value: 1.2 kg/hour
    18. Create: Nominal pressure of natural gas #3333822
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3333823
      Value: 37 mbar
    20. Create: Heat carrier temperature #3333824
      Value: 30 - 76 °С
    21. Create: Temperature in the DHW circuit #3333825
      Value: 35 - 55 °С
    22. Create: Hot water capacity at t 25°C #3333826
      Value: 10.3 l/min
    23. Create: Hot water capacity at t 35°C #3333827
      Value: 7.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3333828
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3333829
      Value: 3 bar
    26. Create: Coaxial chimney diameter #3333830
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3333831
      Value: 400x700x298 mm
    28. Create: Weight #3333832
      Value: 27 kg
    29. Create: Additional Information #3333833
      Value: Efficiency at 30% load - 90.1%
    30. Create: Image #6307570
      URL: https://avatars.mds.yandex.net/get-mpic/4012265/img_id423410269852418047.jpeg/orig
    31. Create: Image #6307571
      URL: https://avatars.mds.yandex.net/get-mpic/4565245/img_id1685952108674911696.jpeg/orig
    32. Create: Image #6307572
      URL: https://avatars.mds.yandex.net/get-mpic/4615030/img_id8614213258709948877.jpeg/orig
    33. Create: Image #6307573
      URL: https://avatars.mds.yandex.net/get-mpic/5234569/img_id8755697142023205205.jpeg/orig
    34. Create: Image #6307574
      URL: https://avatars.mds.yandex.net/get-mpic/1545401/img_id5590039821766841148.jpeg/orig
    35. Create: Image #6307575
      URL: https://avatars.mds.yandex.net/get-mpic/1705228/img_id1748486722302380741.jpeg/orig
    36. Create: Image #6307576
      URL: https://avatars.mds.yandex.net/get-mpic/7430655/img_id5734754034937314557.jpeg/orig
    37. Create: Preview image #6307577
      URL: https://avatars.mds.yandex.net/get-mpic/4012265/img_id423410269852418047.jpeg/orig
  2. Donny Darko 30 April 2023 08:05:26
    Name: Convection gas boiler BAXI MAIN 5 14 F, 14 kW, double-circuit; Catalog: Heating boilers