Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3333772
Value: Gas, convection
Create:
Burner #3333773
Value: Gas
Create:
Number of circuits #3333774
Value: Double-circuit
Create:
Thermal power #3333775
Value: 10.40 - 32 kW
Create:
Thermal load #3333776
Value: 11.90 - 34.50 kW
Create:
The combustion chamber #3333777
Value: Closed
Create:
Efficiency #3333778
Value: 93.2 %
Create:
Control #3333779
Value: Electronic
Create:
Installation #3333780
Value: Wall-mounted
Create:
Primary heat exchanger material #3333781
Value: Copper
Create:
Mains voltage #3333782
Value: Single-phase
Create:
Peculiarities #3333783
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3333784
Value: 60 l
Create:
Expansion tank volume #3333785
Value: 7.5 l
Create:
Equipment #3333786
Value: Built-in boiler, display, room thermostat, remote control
Create:
Fuel #3333787
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3333788
Value: 3.65 cu. m/hour
Create:
LPG consumption #3333789
Value: 2.74 kg/h
Create:
Nominal pressure of natural gas #3333790
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3333791
Value: 37 mbar
Create:
Heat carrier temperature #3333792
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3333793
Value: 5 - 60 °С
Create:
Hot water capacity at t 25°C #3333794
Value: 22 l/min
Create:
Hot water capacity at t 35°C #3333795
Value: 13.5 l/min
Create:
Max. water pressure in the DHW circuit #3333796
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3333797
Value: 3 bar
Create:
Gas connection #3333798
Value: 3/4"
Create:
Heating circuit connection #3333799
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3333800
Value: 1/2"
Create:
Coaxial chimney diameter #3333801
Value: 60/100 mm
Create:
Dimensions WxHxD #3333802
Value: 600x950x466mm
Create:
Weight #3333803
Value: 70 kg
Create:
Additional Information #3333804
Value: Performance at 30% power 90.5%; expansion tank of the DHW circuit 3.5 l; the amount of hot water in the first 30 minutes at ΔТ
Create:
Image #6307551
URL: https://avatars.mds.yandex.net/get-mpic/4887676/img_id2928554080215699869.jpeg/orig
Create:
Image #6307552
URL: https://avatars.mds.yandex.net/get-mpic/5235101/img_id8713449870436097512.jpeg/orig
Create:
Image #6307553
URL: https://avatars.mds.yandex.net/get-mpic/5275484/img_id2934337959108490207.jpeg/orig
Create:
Image #6307554
URL: https://avatars.mds.yandex.net/get-mpic/4590616/img_id538510074308875314.jpeg/orig
Create:
Image #6307555
URL: https://avatars.mds.yandex.net/get-mpic/2008488/img_id8916171684842852852.jpeg/orig
Create:
Image #6307556
URL: https://avatars.mds.yandex.net/get-mpic/5177644/img_id5375723055662812957.jpeg/orig
Create:
Image #6307557
URL: https://avatars.mds.yandex.net/get-mpic/5253277/img_id7174830339497945869.jpeg/orig
Create:
Image #6307558
URL: https://avatars.mds.yandex.net/get-mpic/5255974/img_id1757568649951467728.jpeg/orig
Create:
Image #6307559
URL: https://avatars.mds.yandex.net/get-mpic/5251231/img_id8129699479885863001.jpeg/orig
Create:
Image #6307560
URL: https://avatars.mds.yandex.net/get-mpic/4448884/img_id4520179389221728694.jpeg/orig
Create:
Image #6307561
URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id1343262614000326794.jpeg/orig
Create:
Image #6307562
URL: https://avatars.mds.yandex.net/get-mpic/2017291/img_id5856349004517093639.jpeg/orig
Create:
Image #6307563
URL: https://avatars.mds.yandex.net/get-mpic/1961245/img_id7388072300519226231.jpeg/orig
Create:
Image #6307564
URL: https://avatars.mds.yandex.net/get-mpic/7887763/img_id4539625852990914002.jpeg/orig
Create:
Image #6307565
URL: https://avatars.mds.yandex.net/get-mpic/7716311/img_id6937469167663300268.jpeg/orig
Create:
Image #6307566
URL: https://avatars.mds.yandex.net/get-mpic/4863739/img_id4659890734479680693.jpeg/orig
Create:
Image #6307567
URL: https://avatars.mds.yandex.net/get-mpic/1060343/img_id6388781283278000790.jpeg/orig
Create:
Image #6307568
URL: https://avatars.mds.yandex.net/get-mpic/1923922/img_id5926143144507021577.png/orig
Create:
Preview image #6307569
URL: https://avatars.mds.yandex.net/get-mpic/4887676/img_id2928554080215699869.jpeg/orig
Donny Darko 30 April 2023 08:05:26
Name: Convection gas boiler BAXI NUVOLA-3 Comfort 320 Fi, 32 kW, double-circuit; Catalog: Heating boilers