Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:21:43
Create:
Description #3331795
Value: Type of heating boiler: gas, max. heating power: 29.70 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3331796
Value: Gas, convection
Create:
Burner #3331797
Value: Gas
Create:
Number of circuits #3331798
Value: Double-circuit
Create:
Thermal power #3331799
Value: 14.90 - 29.70 kW
Create:
Thermal load #3331800
Value: 17 - 33 kW
Create:
The combustion chamber #3331801
Value: Closed
Create:
Efficiency #3331802
Value: 90 %
Create:
Control #3331803
Value: Electronic
Create:
Installation #3331804
Value: Floor
Create:
Primary heat exchanger material #3331805
Value: Cast iron
Create:
Mains voltage #3331806
Value: Single-phase
Create:
Peculiarities #3331807
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3331808
Value: 60 l
Create:
Expansion tank volume #3331809
Value: 10 l
Create:
Equipment #3331810
Value: Built-in boiler, display
Create:
Fuel #3331811
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3331812
Value: 3.49 cu. m/hour
Create:
LPG consumption #3331813
Value: 2.56 kg/h
Create:
Nominal pressure of natural gas #3331814
Value: 20 mbar
Create:
Permissible LPG pressure #3331815
Value: 30 mbar
Create:
Heat carrier temperature #3331816
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3331817
Value: 5 - 65 °С
Create:
Hot water capacity at t 25°C #3331818
Value: 17 l/min
Create:
Hot water capacity at t 35°C #3331819
Value: 12.2 l/min
Create:
Max. water pressure in the DHW circuit #3331820
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3331821
Value: 3 bar
Create:
Gas connection #3331822
Value: 1/2"
Create:
Heating circuit connection #3331823
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3331824
Value: 1/2"
Create:
Coaxial chimney diameter #3331825
Value: 60/100 mm
Create:
Dimensions WxHxD #3331826
Value: 650x850x600mm
Create:
Weight #3331827
Value: 192 kg
Create:
Additional Information #3331828
Value: Productivity of hot water for the first 30 minutes at Δt
Create:
Image #6306412
URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id2454436401525618929.jpeg/orig
Create:
Image #6306413
URL: https://avatars.mds.yandex.net/get-mpic/5210428/img_id134516915755634747.jpeg/orig
Create:
Image #6306414
URL: https://avatars.mds.yandex.net/get-mpic/5346941/img_id7078818268010201369.jpeg/orig
Create:
Image #6306415
URL: https://avatars.mds.yandex.net/get-mpic/1884605/img_id4062330813688103854.jpeg/orig
Create:
Image #6306416
URL: https://avatars.mds.yandex.net/get-mpic/5279099/img_id4053711389157007261.jpeg/orig
Create:
Image #6306417
URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id8353054783725591298.jpeg/orig
Create:
Image #6306418
URL: https://avatars.mds.yandex.net/get-mpic/5266697/img_id700991132627665562.jpeg/orig
Create:
Image #6306419
URL: https://avatars.mds.yandex.net/get-mpic/5235242/img_id1644635802618868540.jpeg/orig
Create:
Preview image #6306420
URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id2454436401525618929.jpeg/orig
Donny Darko 30 April 2023 08:05:00
Name: Boiler BAXI 30kW s / c, 2kt, floor SLIM 2.300 Fi; Catalog: Heating boilers