Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:21:35
Create:
Description #3331733
Value: Type of heating boiler: gas, max. thermal power: 22.10 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
Create:
Type of heating boiler #3331734
Value: Gas, convection
Create:
Burner #3331735
Value: Gas
Create:
Number of circuits #3331736
Value: Double-circuit
Create:
Thermal power #3331737
Value: 11.80 - 22.10 kW
Create:
Thermal load #3331738
Value: 13.50 - 24.50 kW
Create:
The combustion chamber #3331739
Value: Open
Create:
Efficiency #3331740
Value: 90.2 %
Create:
Control #3331741
Value: Electronic
Create:
Installation #3331742
Value: Floor
Create:
Primary heat exchanger material #3331743
Value: Cast iron
Create:
Mains voltage #3331744
Value: Single-phase
Create:
Peculiarities #3331745
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3331746
Value: 50 l
Create:
Expansion tank volume #3331747
Value: 10 l
Create:
Equipment #3331748
Value: Built-in boiler, display
Create:
Fuel #3331749
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3331750
Value: 2.59 cu. m/hour
Create:
LPG consumption #3331751
Value: 1.9 kg/hour
Create:
Nominal pressure of natural gas #3331752
Value: 20 mbar
Create:
Permissible LPG pressure #3331753
Value: 30 mbar
Create:
Heat carrier temperature #3331754
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3331755
Value: 5 - 65 °С
Create:
Hot water capacity at t 25°C #3331756
Value: 13 l/min
Create:
Hot water capacity at t 35°C #3331757
Value: 12.1 l/min
Create:
Max. water pressure in the DHW circuit #3331758
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3331759
Value: 3 bar
Create:
Gas connection #3331760
Value: 1/2"
Create:
Heating circuit connection #3331761
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3331762
Value: 1/2"
Create:
Chimney diameter #3331763
Value: 130 mm
Create:
Dimensions WxHxD #3331764
Value: 650x850x600mm
Create:
Weight #3331765
Value: 176 kg
Create:
Additional Information #3331766
Value: Productivity of hot water for the first 30 minutes at Δt
Create:
Image #6306395
URL: https://avatars.mds.yandex.net/get-mpic/4343038/img_id8129537122079928475.jpeg/orig
Create:
Image #6306396
URL: https://avatars.mds.yandex.net/get-mpic/4032471/img_id984515604568951475.jpeg/orig
Create:
Image #6306397
URL: https://avatars.mds.yandex.net/get-mpic/5279099/img_id4053711389157007261.jpeg/orig
Create:
Image #6306398
URL: https://avatars.mds.yandex.net/get-mpic/5326769/img_id3311733134547514522.jpeg/orig
Create:
Image #6306399
URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id831758373269683425.jpeg/orig
Create:
Image #6306400
URL: https://avatars.mds.yandex.net/get-mpic/3611742/img_id8060339707340275955.jpeg/orig
Create:
Image #6306401
URL: https://avatars.mds.yandex.net/get-mpic/5319505/img_id8372991397500414941.jpeg/orig
Create:
Preview image #6306402
URL: https://avatars.mds.yandex.net/get-mpic/4343038/img_id8129537122079928475.jpeg/orig
Donny Darko 30 April 2023 08:05:00
Name: Boiler BAXI 23kW o/k, 2kt, floor SLIM 2.230 i; Catalog: Heating boilers